Evaluation of the Removal Efficiency of Per- and Polyfluoroalkyl Substances in Drinking Water using Nanofiltration Membranes, Active Carbon and Anion Exchange

Klara Lindegren
Abstract:Per- and polyfluoroalkyl substances (PFASs) is a group of man-made, highly persistent chemicals. Due to the specific surface-active attributes of these molecules, applications are numerous and feed an economically important industry. During the last decade, PFASs have been detected globally in the environment, living organisms and tap water. The combination of toxic properties and high bioaccumulative potential, together with the discovery that conventional water treatment methods do not remove PFAS, renders further research on purification methods highly needed. Three techniques of purifying water from PFASs were examined. Nanofiltration technology (NF) is a membrane filtration technique, which produces a purified product (the permeate) by generating an effluent of high contaminant concentration (the reject water). To decontaminate the reject water, adsorption by granular activated carbon (GAC) or anion exchange (AE) have been proposed. The efficiency of these three technologies was studied at Backlosa drinking water treatment plant (DWTP) in Uppsala.A nanofiltration pilot with two 270NF membranes (Dow Filmtech™), connected in series, was used. A high removal efficiency (>90%) was found for all PFASs. Furthermore, it was confirmed that the concentration in the permeate water was a function of the concentration in the incoming raw water; increased PFAS raw water concentration resulted in increased PFAS permeate concentration. Size-exclusion and electrostatic repulsion were deemed important mechanisms. For the comparison of GAC (Filtrasorb 400®) and AE (Purolite® A-600), a column experiment was set up. The perfluoroalkane (-alkyl) sulfonic acids (PFSAs) and perfluorooctanesulfonamide (FOSA) had similar removal efficiencies using both GAC and AE, and the efficiency increased with increasing chain length. AE was found to have a higher average removal efficiency of perfluoroalkyl carboxylic acid (PFCAs) (62-95%) than GAC (49-81%). In conclusion, longer chain length PFASs were removed more effectively than shorter-chained, and the PFSAs and FOSA showed higher removal efficiency compared to the PFCAs. Furthermore, linear isomers were removed more effectively than branched for GAC and AE. In contrast, the opposite was found for the NF membrane, where branched isomers were better retained.
Chemistry,Environmental Science
What problem does this paper attempt to address?