Dichroic Scanning Nonlinear Optical Microscope With Photodetecting Polymer Scanner and Objective Lens With External Back Focal Plane

Naitao Xu,Bei Fang,Jin Cheng,Weiguo Liu,X. Li,Yingshun Xu,Menghua Wang
DOI: https://doi.org/10.1109/JPHOT.2021.3115402
IF: 2.4
2021-10-01
IEEE Photonics Journal
Abstract:In this article authors present a prototype of a dichroic scanning nonlinear optical microscope with a photodetecting polymer Scanner and a customized objective lens with an external back focal plane. Two types of two-axis electromagnetic actuated polymer scanners are manufactured by a standard printed circuit board (PCB) fabrication process. Both scanners share the same overall dimensions of 45 mm by 45 mm. The maximum optical scan angle of a type I scanner is 13 degrees at 420 Hz by the fast axis in resonance and 4 degrees by the slow axis in the linear mode. The type II scanner shows similar performance. A scan lens as well as a tube lens in a conventional nonlinear optical microscope are replaced by placing such a polymer scanner on the external back focal plane of a customized water immersion objective lens. The objective lens has the back working distance of 6 mm, the numerical aperture of 0.7, the front working distance of 1.16 mm, a field of view of 1.67 mm in the diameter and the angle of view of +/−15 degrees. Preliminary imaging results are also presented.
Physics,Engineering
What problem does this paper attempt to address?