Evaporation performance of propane in offset strip-fin plate heat exchanger for refrigerant-based battery thermal management in electric vehicles
Palanisamy Dhamodharan,Mohammad Salman,Rajendran Prabakaran,Sung Chul Kim
DOI: https://doi.org/10.1016/j.applthermaleng.2024.122973
IF: 6.4
2024-03-20
Applied Thermal Engineering
Abstract:This study investigates the potential of refrigerant-based cooling (RC) using a natural refrigerant (propane) and lightweight energy-efficient brazed plate heat exchangers (PHXs) in the battery thermal management systems (BTMSs) of the electric vehicles (EVs). Experimental assessments were conducted to analyze the evaporative heat transfer characteristics of propane within an offset strip-fin flow-structured PHX under various operational conditions resembling the BTMS operation. The battery discharge rates, often represented by the C-rate, are determined by the discharging current relative to the battery's capacity. In this study, a heat generation model based on the C-rate was employed to evaluate the thermal performance of the battery. Parameters, such as mass flux (G) at 30–70 kg/m 2 s, discharge rates (C-rate) of 1, 1.25, and 1.5C, and saturation temperatures (T sat ) of 16–24 °C were explored, with the inlet vapor quality (x in ) in the range of 0.1–0.8. The influence of G and T sat on the heat transfer performance showed that higher G values (60 and 70 kg/m 2 s) achieved the maximum heat transfer coefficients (HTC), which resulted in impractical pressure drops (PD). While higher HTC and lower PD were observed at a T sat of 24 °C, concerns about increased inner wall temperature (T iw ) and safety emerged at this temperature. Hence, the optimum conditions of G (30 and 50 kg/m 2 s) and T sat (16 and 20 °C) were investigated. The average HTC increased by 29, 27, and 21 % at 50 kg/m 2 s compared to that at 30 kg/m 2 s with T sat of 20 °C, resulting in an average of 0.7, 0.9, and 1.2 °C reduction in the T iw for C-rates of 1.5, 1.25, and 1C respectively. Compared to the T sat of 16 °C, higher HTC and lower PD were observed at 20 °C, however, the T iw was in the range of 21.12–20.47 °C for T sat of 20 °C, which is 3.5–4 °C higher than that at T sat of 16 °C. The results from the critical heat transfer coefficient analysis showed that the peak heat dissipation with minimal wall temperature was attained with optimal x m of 0.45–0.5, which enhanced the cooling efficiency for both the G values of 30 and 50 kg/m 2 s, and both the T sat values (16 and 20 °C).
energy & fuels,engineering, mechanical,thermodynamics,mechanics