Assessment of Repeatability, Reproducibility, and Performances of T2 Mapping‐Based Radiomics Features: A Comparative Study

Amandine Crombé,Xavier Buy,Fei Han,Solenn Toupin,Michèle Kind
DOI: https://doi.org/10.1002/jmri.27558
IF: 4.4
2021-02-16
Journal of Magnetic Resonance Imaging
Abstract:<section class="article-section__content"><h3 class="article-section__sub-title section1"> Background</h3><p>Magnetic resonance imaging (MRI)‐based radiomics features (RFs) quantify tumors radiological phenotypes but are sensitive to postprocessing parameters, including the intensity harmonization technique (IHT), while mappings enable objective quantitative assessment.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Purpose</h3><p>To investigate whether T2 mapping could improve repeatability, reproducibility, and performances of radiomics compared to conventional T2‐weighted imaging (T2WI).</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Study Type</h3><p>Prospective.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Subjects</h3><p>Twenty‐six healthy adults.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Field Strength/Sequence</h3><p>Respiratory‐trigged radial turbo spin echo (TSE) multiecho T2 mapping (prototype) and conventional TSE T2WI of the abdomen were acquired twice at 1.5 T.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Assessment</h3><p>T2 maps were reconstructed using a two‐parameter exponential fitting model. Volumes‐of‐interest (VOIs) were manually drawn in six tissues: liver, kidney, pancreas, muscle, bone, and spleen. After co‐registration, conventional T2WIs were processed with two IHTs (standardization [std] and histogram‐matching [HM]) resulting in four paired input image types: initial T2WI, T2WI<sub>std</sub>, T2WI<sub>HM</sub>, and T2‐map. VOIs were propagated to extract 45 RFs from MRI‐1 and MRI‐2 of each image type (LIFEx, v5.10). </p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Statistical Tests</h3><p>Influence of the input data type on RF values was evaluated with analysis of variance. RFs test–retest repeatability and reproducibility over multiple segmentations were evaluated with intra‐class correlation coefficient (ICC). Correlations between k‐means clusters and the six tissues depending on the RFs dataset were investigated with adjusted‐Rand‐index (ARI).</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Results</h3><p>About 41 of 45 (91.1%) RFs were significantly influenced by the input image type (<i>P</i> values &lt; 0.05), which was the most influential factor on repeatability of RFs (<i>P</i>‐value &lt; 0.05). Repeatability ICCs from T2‐map displayed intermediate values between the initial T2WI (range: 0.407–0.736) and the T2WI<sub>HM</sub> (range: 0.724–0.817). The number of RFs with interobserver and intraobserver reproducibility ICCs ≥ 0.90 was 37/45 (82.2%) for T2WI<sub>HM</sub>, 33/45 (73.3%) for T2WI<sub>std</sub>, 31/45 (68.9%) for T2 map, and 25/45 (55.6%) for the initial T2WI. T2 map provided the best tissue discrimination (ARI = 0.414 vs. 0.157 with T2WI<sub>HM</sub>). </p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Data Conclusion</h3><p>T2 mapping provided RFs with moderate to substantial repeatability and reproducibility ICCs, along with the most preserved discriminative information.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Level of Evidence</h3><p>1</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Technical Efficacy</h3><p>1</p></section>
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?