The Micro Wire Detector

B. Adeva,F. Gomez,A. Pazos,R. Pfau,M. Plo,J.M. Rodriguez,P. Vazquez,J. C. Labbe
DOI: https://doi.org/10.1016/S0168-9002%2899%2900555-0
1999-04-30
Abstract:We present the performance of a new proportional gas detector. Its geometry consists of a cathode plane with 70x70 micron apertures, crossed by 25 micron anode strips to which it is attached by 50 micron kapton spacers. In the region where the avalanche takes place, the anode strips are suspended in the gas mixture like in a standard wire chamber. This detector exhibits high rate capability and large gains, introducing very little material.
High Energy Physics - Experiment
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to construct a gas detector suitable for the Large Hadron Collider (LHC) in a high - radiation environment. Specifically, the researchers proposed a new proportional gas detector - the Micro Wire Detector (µWD), aiming to improve the existing Micro - Strip Gas Detector (MSGD). Although the MSGD has good charge - collection characteristics, its gain is limited (usually about 2,000). By reducing the openings on the kapton film, a pattern similar to that of the Gas Electron Multiplier (GEM) is formed on one side of the detector, while on the other side, it is composed of metal strips or wires passing through the kapton holes. This design not only improves the mechanical stability but also allows for the manufacture of finer stripes, thus obtaining a single - stage, high - gain proportional device, combining the focused electric field in the micropores with the standard wire amplification and charge - collection techniques. The main objectives mentioned in the paper include: 1. **Increasing the gain**: By optimizing the design of the detector, a gain of more than 15,000 is achieved. 2. **Enhancing the mechanical stability**: By reducing the length of the suspended parts, the mechanical stability of the detector is improved. 3. **Reducing the amount of materials used**: The materials of the entire detector account for only 0.037% of one radiation length, which helps to reduce the impact on particle trajectories. 4. **Improving the working performance**: The test results show that the detector can still maintain stable performance under high - rate conditions (up to 4×10^5 Hz/mm²), and the gain change is less than 5%. Through these improvements, the researchers hope that the µWD can become an efficient, low - material - consumption, high - rate tracking detector suitable for particle physics experiments in high - radiation environments.