The coupling use of electro-chemical and advanced oxidation to enhance the gaseous elemental mercury removal in flue gas

Limei Cao,Jie Yang,Yi Xu,Wei Sun,Qicheng Shen,Jiacheng Zhou,Ji Yang
DOI: https://doi.org/10.1016/j.seppur.2020.117883
IF: 8.6
2021-02-01
Separation and Purification Technology
Abstract:<p>A novel diffusion electro-chemical combined advanced oxidation reactor offers potential for elemental mercury (Hg<sup>0</sup>) removal in flue gas and shown excellent performance. This study introduced an ultraviolet light into the electric catalytic system to form an UV-electric oxidation system to strengthen Hg<sup>0</sup> removal. Hg<sup>0</sup> removal efficiency in the combined UV-electric oxidation system reached up to 65%. Hg<sup>0</sup> is excited by UV lamp with a wavelength of 253.7 nm, and a very small amount of oxygen contained in high-purity nitrogen can still participate in Hg<sup>0</sup> oxidation reaction. In addition, the Fenton method has also been introduced into the simple electrolysis system. Both the above combined system can improve the efficiency of Hg<sup>0</sup> removal. The electro-chemical GDE was characterized by SEM, BET, and contact angle and gas permeability. The electro-chemical and advanced oxidation process (Fenton method and UV illumination) combined within a system or individually in series were explored the different influencing factors. The gaseous elemental mercury removal mechanism of the combined electro-chemical and advanced oxidation was investigated via combining the experimental data and theoretical reasoning. Electrochemical coupling with other advanced oxidation technologies is a promising technology.</p>
engineering, chemical
What problem does this paper attempt to address?