Dual Fundamental Frequency HSS-Based Reduced Order Impedance Modeling of AC/AC Modular Multilevel Converter for Tundish Heating

Gelin Huang,Fujun Ma,Hongqi Ding,Qixiang Yang,Rui Fan,Lei Wang
DOI: https://doi.org/10.1109/tpwrd.2024.3377807
IF: 4.825
2024-01-01
IEEE Transactions on Power Delivery
Abstract:Due to the specificity of continuous casting production, the application of acac MMC structure in induction heating power supply requires the realization of frequency conversion from grid AC to low and medium single-phase AC, which makes the conventional modeling methods inappropriate. In this article, an HSS-based reduced order impedance model is proposed. Firstly, due to the complexity of the internal harmonics, the harmonic attenuation of the internal signals is calculated quantitatively by analyzing the three-dimensional signal-flow graph and then the harmonic frequencies are truncated, which provide a basis for model simplification. Furthermore, to precisely describe the amplitude-phase characteristics of the acac MMC under different output frequencies, the harmonic state space modeling method is improved by combining the double Fourier integral transform. Finally, the correctness of the frequency analysis and the accuracy of the reduced order model are verified.
engineering, electrical & electronic
What problem does this paper attempt to address?