Discrimination between Healthy and Sick Cardiac Autonomic Nervous System by Detrended Heart Rate Variability Analysis

Y. Ashkenazy,M. Lewkowicz,J. Levitan,S. Havlin,K. Saermark,H. Moelgaard,P.E. Bloch Thomsen
DOI: https://doi.org/10.48550/arXiv.chao-dyn/9810008
1998-10-14
Abstract:Multiresolution Wavelet Transform and Detrended Fluctuation Analysis have been recently proven as excellent methods in the analysis of Heart Rate Variability, and in distinguishing between healthy subjects and patients with various dysfunctions of the cardiac nervous system. We argue that it is possible to obtain a distinction between healthy subjects/patients of at least similar quality by, first, detrending the time-series of RR-intervals by subtracting a running average based on a local window with a length of around 32 data points, and then, calculating the standard deviation of the detrended time-series. The results presented here indicate that the analysis can be based on very short time-series of RR-data (7-8 minutes), which is a considerable improvement relative to 24-hours Holter recordings.
Chaotic Dynamics,Biological Physics,Data Analysis, Statistics and Probability,Medical Physics,Quantitative Biology
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: how to distinguish healthy individuals from patients with cardiac autonomic nervous system dysfunction by analyzing heart rate variability (HRV). Specifically, the author explored a method based on detrended fluctuation analysis (DFA) to determine whether accurate distinction between healthy individuals and patients can be achieved through shorter time series (such as 7 - 8 minutes of electrocardiogram data). ### Problem Background Heart rate variability (HRV) refers to the variation in the time interval between heartbeats (RR interval), and it is considered an important indicator of the health status of the cardiovascular system. Research shows that HRV can be used as a prognostic indicator for multiple diseases, behavioral disorders, mortality risk, and aging. Therefore, establishing a reliable HRV measurement method and being able to distinguish HRV characteristics in different pathological states are of great significance for clinical diagnosis. ### Research Objectives 1. **Verify the effectiveness of short - time series**: Traditional HRV analysis usually requires 24 - hour Holter monitoring data, but this method is time - consuming and not convenient for clinical application. This study aims to explore whether the distinction between healthy individuals and patients can be achieved through electrocardiogram data of shorter time series (such as 7 - 8 minutes). 2. **Propose a new analysis method**: The author proposed a method based on detrended time series (DTS). By removing the trend component in the original RR interval data, the standard deviation after detrending (\(\sigma_d\)) is calculated and used as a measure of HRV. ### Method Overview 1. **Detrending process**: Subtract the moving average within a local window from the original RR interval time series. The window length is 32 data points (that is, approximately 16 - 32 heartbeats). The detrended sequence reflects the fluctuations relative to the local average. 2. **Calculate the standard deviation**: Calculate the standard deviation \(\sigma_d\) of the detrended time series and evaluate its performance at different window scales. 3. **Data analysis**: Use a data set from 33 subjects (including 21 healthy individuals, 9 diabetic patients, and 3 heart disease patients) to analyze the performance of \(\sigma_d\) at different time series lengths to determine the shortest effective time series length. ### Main Findings - **Effectiveness of short - time series**: The research results show that even using 512 data points (about 7 - 8 minutes of electrocardiogram data), HRV characteristics that can almost completely distinguish healthy individuals from patients can still be obtained. - **Optimal window scale**: By comparing the separation effects at different window scales, the author found that the window scale \(m = 5\) (that is, 32 heartbeat cycles) is the optimal choice. ### Conclusion This study proves that through detrended fluctuation analysis (DFA) and detrended time series (DTS) methods, healthy individuals and patients with cardiac autonomic nervous system dysfunction can be effectively distinguished within a shorter time series. This provides a more convenient and efficient HRV analysis tool for clinical applications, especially in cases of limited resources or the need for rapid diagnosis. ### Formula Representation - Moving average: \[ \text{moving\_average}(i)=\frac{1}{2m}\sum_{j = i - m}^{i + m - 1}RR_j \] where \(m\) is half of the window length, and \(RR_j\) is the \(j\)-th RR interval. - Detrended time series: \[ r_i = RR_i-\text{moving\_average}(i) \] - Standard deviation: \[ \sigma_d=\sqrt{\frac{1}{N}\sum_{i = 1}^N r_i^2} \] where \(N\) is the length of the detrended time series. Through these formulas, the author successfully achieved efficient analysis of HRV and demonstrated its potential in clinical applications.