Physical constraints-based terahertz thickness measurement method of thermal barrier coating

Binghua Cao,Tao Deng,Mengbao Fan,Fengshan Sun,Bo Ye
DOI: https://doi.org/10.1016/j.ndteint.2024.103058
IF: 4.683
2024-04-01
NDT & E International
Abstract:Due to the uneven microstructure of the thermal barrier coatings (TBCs) and dispersion effect, there is a discrepancy between the measured terahertz (THz) signals and the theory, which leads to the optimization process of the model inversion method is prone to local extremes. This results in a lack of reliability of THz thickness measurements based on model inversion. A THz inversion method based on physical constraints is proposed to measure the thickness of TBCs. In this paper, we illustrate the characteristics of the THz signal and propose a fitness function suitable for inversion of TBCs thickness. A feature comparison and adaptive mutation combined with teaching-learning-based optimization algorithm (FCAM-TLBO) is also proposed for inverting the theoretical model to extract ceramic layer thickness. The experiments show that the average relative error is less than 0.3 % for thickness measurements of TBC samples, which has better reliability than the conventional inversion methods.
materials science, characterization & testing
What problem does this paper attempt to address?