Catheter Entrapment During Balloon Angioplasty in Patient With In‐Stent Restenosis: An Unusual Complication and Its Surgical Management

Ibrahim Gokşin,A. Baltalarlı,E. Semiz,E. Gurses,M. Saçar,V. Ozcan,H. Sungurtekin
DOI: https://doi.org/10.1111/j.1540-8191.2007.00360.x
IF: 1.778
2007-03-01
Journal of Cardiac Surgery
Abstract:Abstract  Entrapment of coronary angioplasty hardware is one of the rare complications of percutaneous coronary artery interventions. We reported herein a case of 58‐year‐old man with an entrapped balloon catheter and guidewire within the right coronary artery during the application of a conventional balloon angioplasty for in‐stent restenosis. Surgical removal of the entrapped balloon catheter and guidewire was performed successfully with a coronary artery bypass grafting to the affected vessel. The application of the balloon angioplasty for in‐stent restenosis requires every caution against such type of complications.