Impact of Different Valve-in-Valve Positions on Functional Results of the New Generation of Balloon-Expandable Transcatheter Heart Valve

Najla Sadat,Michael Scharfschwerdt,Stefan Reichert,Buntaro Fujita,Stephan Ensminger
DOI: https://doi.org/10.1055/s-0044-1787701
2024-06-19
The Thoracic and Cardiovascular Surgeon
Abstract:Objectives Very precise positioning of the transcatheter heart valve (THV) inside the degenerated SAV is a crucial factor for valve-in-valve (ViV) procedure to achieve optimal hemodynamic results. Therefore, our study aimed to investigate the impact of implantation depth on functional results after ViV procedures in a standardized in vitro setting. Methods THV (SAPIEN 3 Ultra 23-mm size) and three SAV models (Magna Ease, Trifecta, and Hancock II—all 21-mm size) were tested at different circulatory conditions in five different positions of the THV (2–6 mm) inside the SAV. Mean pressure gradient (MPG), effective orifice area (EOA), geometric orifice area (GOA max ), and pinwheeling index (PWI mean ) were analyzed. Results EOA and MPG of the THV did not differ significantly regarding the position inside the Magna Ease and the Hancock II ( p > 0.05). However, EOA differed significantly, depending on the position of the THV inside Trifecta (2 vs. 5 mm; p = 0.021 and 2 vs. 6 mm; p < 0.001). The THV presented the highest EOA (2.047 cm 2 ) and the lowest MPG (5.387 mm Hg) inside the Magna Ease, whereas the lowest EOA (1.335 cm 2 ) and the highest MPG (11.876 mm Hg) were shown inside the Hancock II. Additionally, the highest GOA max and the lowest PWI mean of the THV were noticed inside the Magna Ease. The THV showed lower GOA max and higher PWI mean inside the Trifecta when placed in a deeper position. Conclusion Deep implantation of the SAPIEN 3 Ultra inside the Trifecta correlates with impaired functional results. In contrast, the implantation position of the SAPIEN 3 Ultra inside the Magna Ease and the Hancock II did not have a significant effect on functional results. Data presented at the 37 th Annual Meeting and Scientific Sessions of the European Association for Cardio-Thoracic-Surgery, held on October 4–7, 2023, in Vienna, Austria. The data that support the findings of this study are available from the corresponding author upon reasonable request. Received: 22 March 2024 Accepted: 21 May 2024 Article published online: 18 June 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
surgery,cardiac & cardiovascular systems,respiratory system
What problem does this paper attempt to address?