A new method for measurement of impulsive peak level attenuation of hearing protectors

Cameron Fackler,Dan Gauger,Jeff G. Schmitt,William Murphy,Elliott Berger
DOI: https://doi.org/10.1121/10.0023765
2023-10-01
The Journal of the Acoustical Society of America
Abstract:ASA/ANSI S12.42-2010 contains the first standardized test method for measuring the performance of hearing protection devices (HPDs) with high-level impulsive noise. This standard defines the impulsive peak insertion loss (IPIL) as a time-domain metric that quantifies the reduction in peak sound pressure level provided by an HPD for impulsive noises. However, IPIL as defined in S12.42-2010 is dependent on the spectrum of the impulsive noise source used for measurements of HPDs. Recent studies of HPDs with impulsive noise have led to the investigation of frequency-domain metrics and calculation methods. Using frequency-domain calculations allows the impulsive peak level attenuation to be computed for a wide range of impulsive noises, not only those used for the measurement. Consequently, significant revisions to S12.42 are under consideration and a new standard, ISO 4869-7, is being developed in parallel with the ANSI revision. This presentation highlights key proposals and substantive changes including: measurement and calculation of the frequency-dependent impulsive insertion loss (IIL), incorporation of frequency-domain aspects such as real-ear attenuation at threshold (REAT) limits to attenuation, and a new impulsive peak level attenuation metric (IPLA) to be calculated from the REAT-bounded IIL.
acoustics,audiology & speech-language pathology
What problem does this paper attempt to address?