Paper test strip for fluorescence detection of iron ion based on nitrogen, zinc and copper codoped carbon dots

Dou Yang,Shuhan Jiang,Shuai Zhang,Xiaoyu Fan,Xiaodong Shao,Shuhao Wang,Rui Li,Qiaoli Yue
DOI: https://doi.org/10.1088/2050-6120/ad0648
2023-11-03
Methods and Applications in Fluorescence
Abstract:Abstract In this study, a test strip for fluorometric analysis of iron ion (Fe 3+ ) was constructed based on nitrogen, zinc and copper codoped carbon dots (NZC-CDs) as fluorescence probes. NZC-CDs were synthesized by hydrothermal method. The morphology, size, components, crystal state and optical properties of NZC-CDs were characterized by transmission electron microscope (TEM), Fourier-transform infrared (FT-IR), x-ray photoelectron spectroscopy (XPS), x-ray diffraction (XRD), UV–vis absorption and fluorescence spectroscopy techniques, respectively. NZC-CDs exhibited bright blue fluorescence under UV lamp with a quantum yield at 17.76%. The fluorescence of NZC-CDs was quenched by Fe 3+ possibly due to the static quenching. The possible fluorescence quenching mechanism was also discussed. The quenching fluorescence was linear with the concentration of Fe 3+ in the range of 2.5–400 μ M with a low detection limit of 0.5 μ M. For the convenient detection, the test strips based on filter paper were employed for Fe 3+ assay. Moreover, the present approach was successfully applied in the determination of Fe 3+ in real samples including black fungus, duck blood and pork liver. The sensing method had the potential application in more food analysis.
chemistry, physical, analytical
What problem does this paper attempt to address?