Thermal Tests of Type B Radioactive Transport Package: Experimental Description and Heat Flux Analysis

Yiren Lian,Ning Wang,Changwu Wang,Jin Yan,Lei Chen,Yeming Zhu,Shutang Sun,Hongchao Sun,Guoqiang Li
DOI: https://doi.org/10.1002/pts.2829
2024-05-31
Packaging Technology and Science
Abstract:The fire test of radioactive transport package was carried out by the furnace method. The temperature and heat flux of the package container and the furnace were monitored analysed during the fire test. The result showed that the total heat flux from flame to packaging container by furnace test was greater than the heat flux calculated with empirical formulas. It proved that the furnace method could provide satisfactory thermal environment for the fire test. The design of Type B radioactive transport package should be able to withstand the fire accident scenario in transportation accident conditions. For the simulation of the fire scenario, there are mainly three methods: pool fire test, furnace test and thermal radiation test. This paper tried to carry out the fire test with the furnace method that the conditions in the furnace can be more carefully controlled. The paper described the requirements of fire test, test conditions and measurement test methods and analysed the temperature change of fire site and the heat flux data of the surface of the package during the fire test. The test results seemed that the fire test method could provide satisfactory thermal environment for fire test of Type B radioactive transport package.
food science & technology,engineering, manufacturing
What problem does this paper attempt to address?