Promotion Effect of Solid Screen on the Smoke Extraction of Vertical Shaft in Urban Road Tunnel Fire

Shaogang Zhang,Shanshan Liao,Long Shi,Bin Lin,Jiahao Liu,Jinhui Wang
DOI: https://doi.org/10.1007/s10694-022-01282-7
IF: 3.605
2022-07-02
Fire Technology
Abstract:A series of fire scenarios were investigated numerically in urban road tunnel to evaluate the smoke extraction enhancement of vertical shaft caused by smoke screen. The separating distance between shaft vent and smoke screen is varied from 0 m to 2.1 m. The characteristics of temperature distribution of smoke layer and the variation of velocity vector field under shaft vent are analyzed, meanwhile the smoke extraction efficiency with different shaft-screen distances is also discussed. The results show that the shaft-screen distance has an obvious influence on the smoke temperature distribution during smoke extraction. The curves of smoke extraction efficiency can be divided into three zones in terms of the shaft-screen separating distance, namely the increasing zone ( ), high efficiency zone ( ) and decreasing zone ( ). The increment of smoke gas exhausted from the downstream and two side-edges of shaft vent leads to the significant improvement of total smoke extraction. Generally, the optimal shaft-screen separating distance for the better smoke extraction is 0.3 m ~ 1.5 m under the screen height of 0.9 m ~ 1.5 m. These outcomes provide some basic references for the design of natural ventilation system in urban road tunnel with smoke screen and vertical shaft.
materials science, multidisciplinary,engineering
What problem does this paper attempt to address?