Deep‐learning‐based joint rigid and deformable contour propagation for magnetic resonance imaging‐guided prostate radiotherapy

Iris D. Kolenbrander,Matteo Maspero,Allard A. Hendriksen,Ryan Pollitt,Jochem R. N. van der Voort van Zyp,Cornelis A. T. van den Berg,Josien P. W. Pluim,Maureen A. J. M. van Eijnatten
DOI: https://doi.org/10.1002/mp.17000
IF: 4.506
2024-02-28
Medical Physics
Abstract:Background Deep learning‐based unsupervised image registration has recently been proposed, promising fast registration. However, it has yet to be adopted in the online adaptive magnetic resonance imaging‐guided radiotherapy (MRgRT) workflow. Purpose In this paper, we design an unsupervised, joint rigid, and deformable registration framework for contour propagation in MRgRT of prostate cancer. Methods Three‐dimensional pelvic T2‐weighted MRIs of 143 prostate cancer patients undergoing radiotherapy were collected and divided into 110, 13, and 20 patients for training, validation, and testing. We designed a framework using convolutional neural networks (CNNs) for rigid and deformable registration. We selected the deformable registration network architecture among U‐Net, MS‐D Net, and LapIRN and optimized the training strategy (end‐to‐end vs. sequential). The framework was compared against an iterative baseline registration. We evaluated registration accuracy (the Dice and Hausdorff distance of the prostate and bladder contours), structural similarity index, and folding percentage to compare the methods. We also evaluated the framework's robustness to rigid and elastic deformations and bias field perturbations. Results The end‐to‐end trained framework comprising LapIRN for the deformable component achieved the best median (interquartile range) prostate and bladder Dice of 0.89 (0.85–0.91) and 0.86 (0.80–0.91), respectively. This accuracy was comparable to the iterative baseline registration: prostate and bladder Dice of 0.91 (0.88–0.93) and 0.86 (0.80–0.92). The best models complete rigid and deformable registration in 0.002 (0.0005) and 0.74 (0.43) s (Nvidia Tesla V100‐PCIe 32 GB GPU), respectively. We found that the models are robust to translations up to 52 mm, rotations up to 15∘ , elastic deformations up to 40 mm, and bias fields. Conclusions Our proposed unsupervised, deep learning‐based registration framework can perform rigid and deformable registration in less than a second with contour propagation accuracy comparable with iterative registration.
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?