Quantitative 177Lu SPECT/CT imaging for personalized dosimetry using a ring-shaped CZT-based camera

Rachele Danieli,Martina Stella,Julian Leube,Johannes Tran-Gia,Clementine Marin,Carlos F. Uribe,Bruno Vanderlinden,Nick Reynaert,Patrick Flamen,Hugo Levillain
DOI: https://doi.org/10.1186/s40658-023-00586-z
2023-10-19
EJNMMI Physics
Abstract:Dosimetry after radiopharmaceutical therapy with 177 Lu ( 177 Lu-RPT) relies on quantitative SPECT/CT imaging, for which suitable reconstruction protocols are required. In this study, we characterized for the first time the quantitative performance of a ring-shaped CZT-based camera using two different reconstruction algorithms: an ordered subset expectation maximization (OSEM) and a block sequential regularized expectation maximization (BSREM) combined with noise reduction regularization. This study lays the foundations for the definition of a reconstruction protocol enabling accurate dosimetry for patients treated with 177 Lu-RPT.
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?