Influence of gadolinium, field-strength and sequence type on quantified perfusion values in phase-resolved functional lung MRI

Julian Glandorf,Fynn Brunzema,Filip Klimeš,Lea Behrendt,Andreas Voskrebenzev,Marcel Gutberlet,Marius M. Wernz,Robert Grimm,Frank Wacker,Jens Vogel-Claussen
DOI: https://doi.org/10.1371/journal.pone.0288744
IF: 3.7
2023-08-01
PLoS ONE
Abstract:Purpose The purpose of this study is to evaluate the influences of gadolinium-based contrast agents, field-strength and different sequences on perfusion quantification in Phase-Resolved Functional Lung (PREFUL) MRI. Materials and methods Four cohorts of different subjects were imaged to analyze influences on the quantified perfusion maps: 1) at baseline and after 2 weeks to obtain the reproducibility (26 COPD patients), 2) before and after the administration of gadobutrol (11 COPD, 2 PAH and 1 asthma), 3) at 1.5T and 3T (12 healthy, 4 CF), and 4) with different acquisition sequences spoiled gradient echo (SPGR) and balanced steady-state free precession (bSSFP) (11 COPD, 7 healthy). Wilcoxon-signed rank test, Bland-Altman plots, voxelwise Pearson correlations, normalized histogram analyses with skewness and kurtosis and two-sample Kolmogorov-Smirnov tests were performed. P value ≤ 0.05 was considered statistically significant. Results In all cohorts, linear correlations of the perfusion values were significant with correlation coefficients of at least 0.7 considering the entire lung ( P <0.01). The reproducibility cohort revealed stable results with a similar distribution. In the gadolinium cohort, the quantified perfusion increased significantly ( P <0.01), and no significant change was detected in the histogram analysis. In the field-strength cohort, no significant change of the quantified perfusion was shown, but a significant increase of skewness and kurtosis at 3T ( P = 0.01). In the sequence cohort, the quantified perfusion decreased significantly in the bSSFP sequence ( P <0.01) together with a significant decrease of skewness and kurtosis ( P = 0.02). The field-strength and sequence cohorts had differing probability distribution in the two-sample Kolmogorov-Smirnov tests. Conclusion We observed a high susceptibility of perfusion quantification to gadolinium, field-strength or MRI sequence leading to distortion and deviation of the perfusion values. Future multicenter studies should strictly adhere to the identical study protocols to generate comparable results.
multidisciplinary sciences
What problem does this paper attempt to address?