Bronchodilator Efficacy of High-Flow Nasal Cannula in COPD: Vibrating Mesh Nebulizer Versus Jet Nebulizer

Itthiphat Arunsurat,Nuttapol Rittayamai,Benjamas Chuaychoo,Suwat Tangchityongsiva,Simaporn Promsarn,Somruthai Yuenyong,Chung-Wai Chow,Laurent Brochard
DOI: https://doi.org/10.4187/respcare.11139
2023-08-22
Respiratory Care
Abstract:BACKGROUND: Jet nebulizers are commonly used for bronchodilator therapy in chronic obstructive pulmonary disease (COPD). High-flow nasal cannula with vibrating mesh nebulizer (HFNC-VMN) is a recently developed system; however, few studies have compared the efficacy of bronchodilator administration via HFNC-VMN to jet nebulizer in stable COPD. This study aimed to compare the effect of salbutamol administered via HFNC-VMN versus jet nebulizer, on airway and lung function in patients with stable COPD. METHODS: This randomized non-inferiority crossover physiologic study enrolled patients with stable COPD. Salbutamol was nebulized via HFNC-VMN or jet nebulizer in random order with a 4-hour washout period between crossover sequences. Spirometry, lung volume, and impulse oscillometry were performed at baseline and after each intervention. The primary outcome was change in forced expiratory volume at 1 second (FEV1) from baseline. Secondary outcomes included changes in other respiratory related parameters and nebulization time compared between the two devices. RESULTS: Seventeen subjects were enrolled. HFNC-VMN and jet nebulizer both significantly improved FEV1 from baseline (P = .005 and P = .002, respectively). The difference between respiratory resistance at 5 Hz and 20 Hz significantly decreased after HFNC-VMN compared to baseline (P = .02), while no significant change was observed after jet nebulizer (P = .056). Area of reactance and resonant frequency of reactance were both significantly decreased (P = .035 and P = .03, respectively), and respiratory reactance at 5 Hz significantly increased (P = .02) in the HFNC-VMN group compared to baseline indicating improved lung mechanics, with no significant changes with the jet nebulizer. HFNC-VMN had a shorter nebulization time (6 [5-9] versus 20 [16-22] minutes, respectively; P < .001). CONCLUSIONS: Bronchodilator therapy via HFNC-VMN is not inferior to jet nebulizer for patients with stable COPD, and can significantly improve airway oscillometry mechanics, and decrease nebulization time compared to jet nebulizer.
respiratory system,critical care medicine
What problem does this paper attempt to address?