Unlocking ultimate precision of intensity and area ratio measurements in Raman spectroscopy: Insights from simulation, experimentation, and theory and implications for isotope ratio analysis

Yuuki Hagiwara,Lena Yokokura,Junji Yamamoto
DOI: https://doi.org/10.1002/jrs.6594
IF: 2.727
2023-09-16
Journal of Raman Spectroscopy
Abstract:Through simulation, experimentation, and theoretical investigation, we identified the parameters which strongly influence precision of intensity and area ratio: (1) the weaker peak intensity Iw; (2) the ratio of the bandwidth to pixel resolution of the weaker peak Γw/Δxw; (3) the degree of detector saturation; (4) the noise ratio, σD2+σR2/σS2 , with readout noise σR, dark noise σD, and shot noise σS; (5) drift; and (6) sample size. The intensity ratio (αI) and area ratio (αA) obtained using Raman spectroscopy are used widely to characterize the physical properties of gases, fluids, and solids, but the underlying parameters which affect their precision (σαI and σαA ) have not been elucidated. We use simulations, experiments, and theoretical analyses to investigate the effects of instrumental performance, analytical conditions, and sample size on σαI and σαA . We identified the parameters which strongly influence σαI : (1) the weaker peak intensity Iw; (2) the ratio of the bandwidth to pixel resolution of the weaker peak Γw/Δxw; (3) the degree of detector saturation; (4) σD2+σR2/σS2 with readout noise σR, dark noise σD, and shot noise σS; (5) drift; and (6) sample size. Theoretical and simulation results show that, when Γw/Δxw ≪ (Γs/Δxs)/αI, increasing Iw or Γw/Δxw by n times can improve σαI by a factor of n . Results showed that σD2+σR2/σS2 is a measure of how much the achievable σαI in the experiment differs from that under ideal analytical conditions (i.e., σD2+σR2≪σS2 ). When σD2+σR2≪σS2 is not the case (i.e., when Iw is low), reducing σD or σR by decreasing the readout speed, setting a lower charge coupled device (CCD) sensitivity, reducing number of readouts, or narrowing vertical binning width can improve σαI . We demonstrated that evaluations of σαI or σαA based on small sample sizes can engender physically unattainable precision. When the sample size is n = 5, 10, or 20, the average uncertainties of σαI and σαA correspond, respectively, to approximately 30%, 20%, and 15%. Giving an accurate and comparable assessment for σαI and σαA necessitates the reporting of intensity (in units of electrons), bandwidth, Δx, and the sample size.
spectroscopy
What problem does this paper attempt to address?