Improvement of Prior Image for Metal Artifact Reduction of Computed Tomography

Wenwu Sun,Tiange Zhuang,Siping Chen
DOI: https://doi.org/10.1007/s12204-023-2643-6
2023-08-24
Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University
Abstract:It is not easy to reduce the metal artifacts of computed tomography images. However, the pixel values inside the metal artifact regions vary smoothly, while those on the borders of the metal and the bone regions vary sharply. When the Canny operation by adaptive thresholding is conducted on the raw image, the almost continuous edges can be formed obviously on the borders of the metal and the bone regions, but this kind of information cannot be formed for the metal artifact regions. In this paper, by searching the closed areas formed by the border edges of the bone regions in the Canny image, the metal artifact regions, which are very difficult to discriminate only by intensity thresholding, can be excluded effectively. A novel prior image-based method is thus developed for metal artifact reduction. The experiments demonstrate that the proposed method can be realized easily and reduce the metal artifacts effectively even if multiple large metal objects exist simultaneously in the image. The method is suitable for the clinical application.
What problem does this paper attempt to address?