Evaluation of a rapid lateral flow assay for the detection of taeniosis and cysticercosis at district hospital level in Tanzania: A prospective multicentre diagnostic accuracy study
Inge Van Damme,Chiara Trevisan,Mwemezi Kabululu,Dominik Stelzle,Charles E Makasi,Veronika Schmidt-Urbaneja,Kabemba E Mwape,Chishimba Mubanga,Gideon Zulu,Karen Schou Møller,Famke Jansen,Dries Reynders,John Noh,Sukwan Handali,Emmanuel Bottieau,Andrea S Winkler,Pierre Dorny,Pascal Magnussen,Sarah Gabriël,Bernard Ngowi
DOI: https://doi.org/10.1101/2024.06.24.24309388
2024-06-24
Abstract:The TS POC test, Taenia solium point-of-care test, is a two-strip lateral flow assay using the recombinant antigen rES33 on the TS POC T test strip, and rT24H on the TS POC CC test strip, to detect antibodies against T. solium taeniosis and cysticercosis, respectively.
The objective of this study was to assess the diagnostic performance of the TS POC test for the detection of T. solium taeniosis and cysticercosis in individuals attending district hospitals in Tanzania.
In this prospective two-phase diagnostic accuracy study, we recruited participants aged 10 and above, excluding pregnant women and those with acute severe illness. Participants were consecutively recruited in three cohorts according to their signs/symptoms: compatible with neurocysticercosis (cohort 1), intestinal worm infections (cohort 2), and other symptoms (cohort 3). Lacking a gold standard test for both infections, evaluating the diagnostic accuracy measures was done using the results of different coprological and serological tests in a Bayesian Latent Class Model approach.
The TS POC test was conducted on 601 participants in cohort 1, 1661 participants in cohort 2, and 662 participants in cohort 3. Most individuals tested negative on both TS POC test strips, with proportions of 83% (n = 496), 97% (n = 1613) and 97% (n = 641) in cohorts 1, 2 and 3, respectively. Sensitivity values for the TS POC T test strip were 50.2% [4.9 - 96.4], 40.8% [2.2 - 95.2], and 40.4% [2.3 – 95.0], while specificity values were 98.6% [97.1 - 99.6], 99.3% [98.7 - 99.7] and 99.4% [98.5 - 99.9], respectively. For the TS POC CC test strip, the sensitivity was 77.5% [37.8 - 99.2], 24.9% [95% CI 6.4 - 52.7] and 44.2% [6.6 - 91.5], and the specificity 92.3% [86.5 - 98.8], 99.1% [97.8 - 100], and 98.1% [96.1 - 99.7] across the respective cohorts.
Although the TS POC test has a suboptimal sensitivity, it demonstrates a high specificity, which may have clinical utility to guide treatment and diagnostic decisions, or in epidemiological studies. An important strength of this study lies in its assessment of the TS POC test under real-world conditions, revealing divergent estimates across distinct cohorts. The study underscores the suboptimal performance of existing tests under field conditions, emphasizing the need for the development and validation of better diagnostic tests.