Calculation of wakefield in plasma-filled dielectric capillaries generated by a relativistic electron beam *
Chen Li,H. Zha,Chuanxiang Tang,W. Gai
2013-01-01
Abstract:In this paper we give an analytical solution of TM0n mode for wakefields generated by a relativistic electron beam passing through plasma-filled capillary waveguides. The numerical solution shows that the fields of TM0n modes could not be ignored when the plasma wave length is comparable with the effective radius of the capillary tube, which means that the boundaries are not shielded completely by plasma. Numerical examples are given in several typical cases. MOTIVATION Acceleration gradient in plasma wakefields accelerators can be much higher than those of conventional RF accelerators [1-3], which is attractive for the reason of reducing the size and cost of high energy electron accelerators. In recent studies and experiments [4-6], one promising way in driving a plasma wave with strong longitudinal electric field, is using a capillary discharge waveguide with an intense electron beam passing through. In these studies, the regime of plasma waves, known as blowout or bubble regime, is highly nonlinear, where the drive pulse is intense and short enough to drive the first wake into breaking. In this regime, only one wakefield bubble is loaded with electrons, which means nonlinear positron wakes are much smaller than those of the corresponding electron case [7]. However, for the possible applications of plasma wakefields accelerators for future high energy electron-positron colliders, not only electrons but also injected positrons need to be accelerated to high energy. In order to accelerate positrons by plasma wakefields, plasma waves could be switched from blowout regime to linear regime by decreasing the plasma density. In this case, there will be accelerating fields for positions as the same gradient as for electrons. Under the linear responses and no boundaries assumptions, wakefields in the plasma generated by a charged beam were completely studied in 1980s [8]. However the cylindrical capillary tube is a slow wave structure similar to a conventional dielectric wakefields accelerator. Therefore, eigen RF waves of Cherenkov radiations will be excited when a charged beam passing through [9-11], as well as the plasma waves. For the blowout regime, electrons density in the plasma is usually 10~10 cm, and the corresponding plasma wavelength is much smaller than the radius of capillary tube (~100um). Because of the shielding effects by the plasma, it approaches to no boundaries case with nearly zero eigen RF fields, which can also be seen in our numerical results. When the plasma electron density is down to some value in the linear regimes, the eigen RF fields will be several percent of those of plasma waves or even more, which means eigen RF modes could not be ignored in this case. Some numerical examples are given as a reference. ANALYTICAL SOLUTIONS FOR THE WAKE FIELDS The plasma filled dielectric capillary tube is a cylindrical structure which consists of a plasma channel with radius a surrounded by an isotropic dielectric with radius b, and outmost metallic waveguide. Figure 1: Cross-section of a plasma filled dielectric tube. The plasma can be seen as a collective dielectric in the approximation of linear regime with a dielectric constant,