Development and Validation of Novel Digital Retinoscopy to Analyze Total Refraction of the Eye
Haohan Zou,Shenda Shi,Xiaoyan Yang,Jiaonan Ma,Xuan Chen,Yibing Wang,Mingdong Zhang,Jiaxin Song,Yanglin Jiang,Lihua Li,Xin He,Shengjin Wang,Meina Song,Yan Wang
DOI: https://doi.org/10.2139/ssrn.4098702
2022-01-01
Abstract:Background and Objectives: Uncorrected refractive errors are the leading cause of vision impairment worldwide. The prevalence of myopia and myopic astigmatism has dramatically increased and caused deterioration of retinal images. To date, there are no appropriate methods to analyze the total refraction of the eye. Color fundus images contain a wealth of visible and invisible information, including anatomical structure and complete state of the eye, which might provide total refraction. We aimed to develop a novel fusion-model-based digital retinoscopy for analyzing the total refraction of the eye and validate it by comparing it with cycloplegic refraction.Methods: This population-based, comparative study retrospectively collected 11,973 fundus images from May 1, 2020, to November 20, 2021. The fusion model was constructed based on regression and classification using the voting algorithm to analyze the total refraction of the eye. The mean absolute error was applied to evaluate the performance of the regression and fusion models of spherical and cylinder power. The accuracy, sensitivity, specificity, area under the receiver operating characteristic curve and F1-score were used to evaluate the classification model of the cylinder axis.Results: Overall, 7,873 images were included in the analyses following cleaning. For spherical and cylinder powers, the mean absolute error values for the fusion model between total and cycloplegic refraction were 0.50 D and 0.31 D, representing increases of 29.41% and 26.67%, respectively, when compared with the single models. The correlation coefficients were r=0.949 (95% confidence interval: 0.942–0.956), and r=0.807 (95% confidence interval: 0.781–0.830), respectively. For axis analysis, the accuracy, specificity, sensitivity, and area under the curve value of the classification model were 0.89 (95% confidence interval: 0.816–0.964), 0.941 (95% confidence interval: 0.849–0.981), 0.882 (95% confidence interval: 0.776–0.944), and 0.814 (95% confidence interval: 0.708–0.902), respectively, and the F1-score was 0.88.Conclusion: Digital retinoscopy based on the fusion model successfully identified the total refraction of the eye, not only spherical power but also cylinder power and axis. The results show a strong correlation to the cycloplegic refraction. This work provides more comprehensive retinal information and highlights the potential clinical value of fundus images.