Failure distribution and reliable analysis of ferroelectric ceramics under pulsed electric field

Fuping Zhang,Xiqing Li,Jinmei Du,Yusheng Liu,Fuqing Ye,
DOI: https://doi.org/10.7498/aps.73.20231354
IF: 0.906
2024-01-01
Acta Physica Sinica
Abstract:Dielectric breakdown at high electric field plays an important role on the application of ferroelectric ceramics. In this paper, failure probability versus electric shock time of ferroelectric ceramics under positive pulse electric field has been statistic. The failure probability distribution of ceramics after 10 times electric shock is studied. Piezoelectric constant, P-E loop of ferroelectric ceramics after 10 thousand times electric shock are measured and the breakdown mechanism is discussed. Results indicate that the relation of failure probability and electric shock time of ferroelectric ceramics is bath-tube curve and failure probability of samples subjected to 10 time electric shock decrease to 4 magnitudes than that of origin sample. The samples subjected to positive pulse electric field many times do not show obvious fatigue and aging effect according to the results of piezoelectric constant and P-E loop. So pulse electric field loading at 4.5 kV/mm is close to none destructive inspection. Considering the spread speed of cracks, rupture of ferroelectric ceramics under pulsed electric field roots from extending and connection of multi-cracks from multi-defects.
physics, multidisciplinary
What problem does this paper attempt to address?