Recurrence Detection by Hybrid [18F]FDG‐PET in Advanced Head and Neck Squamous Cell Carcinoma

Oliver P. Sutter,Alexander Maurer,Thomas M. Stadler,Martin Lanzer,Martin W. Huellner,Martina A. Broglie
DOI: https://doi.org/10.1002/hed.27997
2024-11-10
Head & Neck
Abstract:Background In the clinical management of advanced stage head and neck squamous cell carcinoma, the use of hybrid [18F]FDG‐PET imaging is well established. However, there is ongoing debate regarding the optimal frequency of hybrid PET scans to be included in follow‐up protocols, particularly if the initial post‐therapeutic scan is negative. Methods We conducted a single‐center 10‐year retrospective study involving all patients who underwent hybrid PET scans for the follow‐up of advanced stage head and neck cancer. A total of 285 patients were included. Results Out of 199 patients with a negative 3‐month hybrid PET, 15% subsequently developed a recurrence during further follow‐up. Notably, 90% of these recurrences were detected by hybrid PET. Conclusion Fifteen percent of patients with a negative 3‐month hybrid PET experienced a recurrence. Given that the majority of recurrences were detected by hybrid PET scans, there is a compelling argument for incorporating regular repetitive scans during follow‐up.
surgery,otorhinolaryngology
What problem does this paper attempt to address?