Modulating the Microenvironment of Coumarin Dyes within Multihierarchical Supraparticles: En Route toward Versatile Luminescent Dual‐Threshold Temperature Indicators with Ratiometric Readout

Jakob Reichstein,Leoni Luthardt,Valentino Gabriel Martello,Andrea Pianetti,Susanne Wintzheimer,Karl Mandel
DOI: https://doi.org/10.1002/adom.202303346
IF: 9
2024-02-17
Advanced Optical Materials
Abstract:The confined space within micrometer‐sized, multihierarchical hybrid organic‐inorganic supraparticles provides an attractive microenvironment to achieve functional material properties via the synergistic interplay of nanoparticles and molecules. Herein, the programmable, temperature‐induced modulation of the microenvironment of coumarin dyes within multihierarchical supraparticles is demonstrated, yielding versatile, eye‐readable, customizable luminescent dual‐threshold temperature indicator additives with a broad working range from 60–200 °C. Temperature indicators trace (un)desired thermal impacts across their thermal history upon readout at every point of interest via defined irreversible signal changes. Ratiometric luminescent temperature indicators are attractive due to their fast, sensitive, contactless, spatially‐resolved, and self‐referenced readout. However, they have a limited working range as commonly only one specific temperature‐induced physicochemical effect is exploited. Herein, dual‐threshold temperature indicator supraparticles (SPs) are introduced that expand the working range of individual luminescent probes and enhance the extractable information on the thermal history. These SPs derive their functionality from the synergistic interplay of three spectrally distinguishable luminescent species assembled in one multihierarchical, micrometer‐sized particle of hybrid organic‐inorganic nature. This engineered nanostructure enables the stepwise modulation of the physicochemical microenvironment of two incorporated coumarin species at programmable threshold temperatures, resulting in distinct changes in their emission. As these changes are based on dye‐specific mechanisms that are induced in consecutive temperature regimes, the SPs achieve a scarcely reported broad working range (60–200 °C) with temperature‐dependent response times of minutes to seconds. From a broader perspective, the conceptualized SPs pioneer in how multiple individual luminescent probes with different excitation‐emission properties and indicator mechanisms are synergistically united in one advanced indicator system by precise material engineering.
materials science, multidisciplinary,optics
What problem does this paper attempt to address?