Ultrasensitive Exosome Detection by Modularized SERS Labeling for Postoperative Recurrence Surveillance

Chenchen Fan,Na Zhao,Kai Cui,Gaoxian Chen,Yingzhi Chen,Wenwei Wu,Qingyun Li,Yanna Cui,Ruike Li,Zeyu Xiao
DOI: https://doi.org/10.1021/acssensors.1c00890
IF: 8.9
2021-09-02
ACS Sensors
Abstract:Exosome-based liquid biopsy holds great potential in monitoring tumor progression. Current exosome detection biosensors rely on signal amplification strategies to improve sensitivity; however, these strategies pay little attention to manipulating the number of signal reporters, limiting the rational optimization of the biosensors. Here, we have developed a modularized surface-enhanced Raman spectroscopy (SERS) labeling strategy, where each Raman reporter is coupled with lysine as a signal-lysine module, and thus the number of Raman reporters can be precisely controlled by the modularized solid-phase peptide synthesis. Using this strategy, we screened out an optimum Raman biosensor for ultrasensitive exosome detection, with the limit of detection of 2.4 particles per microliter. This biosensor enables a successful detection of the tumor with an average diameter of approximately 3.55 mm, and thus enables successful surveillance of the postoperative tumor recurrence in mice models and distinguishing cancer patients from healthy subjects. Our work provides a de novo strategy to precisely amplify signals toward a myriad of biosensor-related medical applications.The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acssensors.1c00890.Experimental details; preparation and characterization of exosomes (Figure S1); preparation and characterization of compound 1 (Figure S2); characterization of the EpCAM aptamer carrying single Raman reporter (Figure S3); detection of A549 cells derived exosomes by SERS EpCAM-aptasensors carrying single Raman reporter and SERS random sequence-sensors carrying single Raman reporter (Figure S4); mass spectra of signal amplified parts carrying (a) 5, (b) 8, and (c) 10 Raman reporters (Figure S5); gel electrophoresis image for EpCAM aptamer carrying eight Raman reporters (Figure S6); quantitative analysis of A549 cell-derived exosomes by ELISA (Figure S7); linear range of exosome detection in plasma by SERS EpCAM-aptasensors carrying eight Raman reporters (Figure S8); stability of the SERS EpCAM-aptasensors for plasma exosome detection (6.00 × 107/mL) in three consecutive weeks (Figure S9); and correlation of the SERS signal with the tumor size of NSCLC mice models (Figure S10). Tables S1–S5 (PDF)This article has not yet been cited by other publications.
chemistry, multidisciplinary, analytical,nanoscience & nanotechnology
What problem does this paper attempt to address?