CLINICAL COMPARISON OF TWO INSERTION METHODS FOR I-GEL PLACEMENT: STANDARD VERSUS ROTATIONAL TECHNIQUE

Namrata A Shah,Sreetha Reddy,Nidhi Jayeshbhai Sejpal,Harsh Malkan,Sharan V
DOI: https://doi.org/10.36106/gjra/8501387
2023-06-15
Global Journal For Research Analysis
Abstract:Use of I-Gel, a2nd generation Supraglottic airway device, has some advantages over endotracheal intubation, such as quick and ease of placement, devoid of hemodynamic response of laryngoscopy, lesser requirement for neuromuscular blockade and less chances of sore throat and cough at removal, dysphagia or dysphonia. A prospective randomized controlled interventional single blind study was conducted on 100 patients for comparison of 2 insertion methods for I-Gel placement after into 2 groups of 50 each- Group S for Standard method and Group R for Rotational method. We concluded that I-Gel insertion using Rotational technique has higher rst attempt successful insertion rate, easier insertion and less mucosal damage.
What problem does this paper attempt to address?