Vacuum Preloading Combined with Intermittent Electro-Osmosis for Dredged Slurry Strengthening
Feiyu Liu,Hongtao Fu,Jie Zhou,Jun Wang,Yuanqiang Cai,Ran Zhao,Xiaoming Lou,Yawei Jin,Wenxi Yuan
DOI: https://doi.org/10.1520/GTJ20180234
2020-01-01
Geotechnical Testing Journal
Abstract:Vacuum electro-osmosis is a useful method for strengthening dredged slurry; however, this technique is not widely applied because of its high power consumption and decreased efficiency in the later stages. Appropriate current intermittence is an important approach to improving the efficiency and reducing the power consumption of the electro-osmosis process. Thus, vacuum preloading combined with intermittent electro-osmosis has been proposed; however, relevant research is lacking, and the conditions for optimized current intermittence remain uncertain. In this study, laboratory experiments are performed to investigate the influence of various current intermittence frequencies on the treatment of six dredged slurry specimens using vacuum preloading combined with intermittent electro-osmosis. The experimental findings indicate that an optimal ratio of the on and off times exists, which can effectively improve soil strength and reduce power consumption. Furthermore, for the same time ratio, treatment with a comparatively short electrification period yields higher efficiency. However, an excessively small time ratio yields lesser improvement than that obtained with continuous electrification.