Analyzing Cooling Island Effect of Urban Parks in Zhengzhou City: A Study on Spatial Maximum and Spatial Accumulation Perspectives

Manting He,Chaobin Yang
DOI: https://doi.org/10.3390/su16135421
IF: 3.9
2024-06-27
Sustainability
Abstract:As a result of urbanization, cities worldwide are experiencing urban heat island (UHI) challenges. Urban parks, which are essential components of urban blue and green landscapes, typically have lower temperatures in providing outdoor comfort than their surroundings with impervious surfaces. This phenomenon, known as the park cooling island effect (PCIE), has been recognized as an effective approach to mitigate the negative effects of the UHI in the context of sustainable development of urban environment. To cope with the serious UHI challenge and to guide urban park planning and design for Zhengzhou City, which is one of the China's new first-tier cities, 35 urban parks in the city were analyzed in this study. Remotely sensed land surface temperature (LST) and reflectance images by Landsat 9 and Sentinel-2 were selected as data sources. A cubic polynomial model that depicts the relationship between the LST and the distance from the park edge was first built for each park. Based on this model, the spatial maximum perspective metrics (including the park cooling area (PCA) and park cooling efficiency (PCE)) and the spatial accumulation perspective metrics (including park cooling intensity (PCI) and park cooling gradient (PCG)) were calculated to quantify the PCIE of each park. The 35 parks were divided into three groups using the hierarchical clustering method for further analysis. For each group, the metrics of the PCIE were statistically analyzed, and the main factors influencing the PCIE were identified by the Spearman correlation coefficient. The results indicate the following: (1) The 35 urban parks exhibit an obvious PCIE. The maximum cooling distance is 133.95 ± 41.93 m. The mean LST of the park is 3.01 ± 1.23 °C lower than that within the maximum cooling distance range. (2) The PCIE varies among different types of parks. Parks with large areas and covered by certain water bodies generally exhibit higher PCA, PCI, and PCG values. However, parks with small areas and mainly covered by vegetation show higher PCE values, which makes them more economical in exerting the PCIE. (3) Park area and landscape shape index (LSI) were positively correlated with PCA, PCI, and PCG. However, there is a threshold in the relationship between the park area and the PCI. A park area of approximately 19 ha can produce a higher PCI than a smaller one. In central urban areas with limited space, parks with small areas, complex shapes, and predominant vegetation coverage can be designed to achieve higher cooling efficiency.
environmental sciences,environmental studies,green & sustainable science & technology
What problem does this paper attempt to address?
### Problems the Paper Aims to Solve This paper aims to address the impact of the Urban Heat Island (UHI) effect on urban environments and provide scientific basis for the planning and design of urban parks by analyzing the Park Cooling Island Effect (PCIE) of 35 urban parks in Zhengzhou. Specifically, the research objectives include: 1. **Comprehensive evaluation of the PCIE of 35 urban parks in Zhengzhou under extreme summer heat conditions**: Quantitative assessment from the perspectives of spatial maximum and spatial accumulation. 2. **Investigate the differences in PCIE among different types of parks**: Understand their performance in PCIE through classification analysis of different types of parks. 3. **Identify the main factors affecting PCIE**: Determine which factors have the greatest impact on PCIE through the analysis of park characteristics. ### Research Background With the acceleration of urbanization, the Urban Heat Island effect has become a major challenge faced by cities globally. Urban parks, as an important part of urban blue-green infrastructure, usually have lower temperatures than the surrounding hardened surfaces and have a significant cooling effect. This phenomenon is known as the Park Cooling Island Effect (PCIE) and is considered one of the effective methods to mitigate the Urban Heat Island effect. However, how to reasonably design and plan urban parks to maximize their cooling effect remains a problem that requires in-depth research. ### Research Methods 1. **Data Collection**: - Use Landsat 9 and Sentinel-2 satellite remote sensing images to obtain land surface temperature (LST) and reflectance data. - Extract park boundary data from Gaode Map and select 35 parks larger than 1 hectare and located in the urban core area for the study. 2. **Quantitative Evaluation of PCIE**: - Construct a cubic polynomial model to describe the relationship between LST and the distance from the park boundary. - Calculate indicators from the spatial maximum perspective (such as Park Cooling Area PCA and Park Cooling Efficiency PCE) and spatial accumulation perspective (such as Park Cooling Intensity PCI and Park Cooling Gradient PCG). 3. **Selection and Analysis of Influencing Factors**: - Select six factors for analysis: park area, Landscape Shape Index (LSI), vegetation proportion (Pv), water body proportion (Pw), vegetation proportion within the buffer zone (Bv), and built-up area proportion (Bb). - Use hierarchical clustering to classify the 35 parks into three categories and analyze the relationship between influencing factors and PCIE indicators through Spearman correlation coefficient. ### Main Findings 1. **All 35 urban parks exhibit significant PCIE**: The maximum cooling distance is 133.95±41.93 meters, and the average LST within the park is 3.01±1.23°C lower than the LST within the maximum cooling distance range. 2. **Differences in PCIE among different types of parks**: Large parks with certain water bodies usually show higher PCA, PCI, and PCG values; while small parks mainly covered with vegetation show higher PCE values, being more cost-effective. 3. **Park area and Landscape Shape Index (LSI) are positively correlated with PCA, PCI, and PCG**: However, there is a threshold between park area and PCI, with a park area of about 19 hectares producing higher PCI values. In the limited space of the central urban area, higher cooling efficiency can be achieved by designing small, complex-shaped parks mainly covered with vegetation. ### Conclusion This study provides a scientific basis for the planning and design of urban parks through quantitative evaluation and multi-factor analysis, helping to mitigate the Urban Heat Island effect and improve the urban ecological environment.