Comparative analysis of hemoglobin, potassium, sodium, and glucose in arterial blood gas and venous blood of patients with COPD

Sitian Tang,Zhu Mei,Dongmei Huang,Ling Liu,Lunyu Yang,Dan Yin,Liyi Hu
DOI: https://doi.org/10.1038/s41598-024-55992-9
IF: 4.6
2024-03-03
Scientific Reports
Abstract:The study aims to assess the accuracy of the arterial blood gas (ABG) analysis in measuring hemoglobin, potassium, sodium, and glucose concentrations in comparison to standard venous blood analysis among patients diagnosed with chronic obstructive pulmonary disease (COPD). From January to March 2023, results of ABG analysis and simultaneous venous blood sampling among patients with COPD were retrospectively compared, without any intervention being applied between the two methods. The differences in hemoglobin, potassium, sodium, and glucose concentrations were assessed using a statistical software program (R software). There were significant differences in the mean concentrations of hemoglobin ( p < 0.001), potassium ( p < 0.001), and sodium ( p = 0.001) between the results from ABG and standard venous blood analysis. However, the magnitude of the difference was within the total error allowance (TEa) of the United States of Clinical Laboratory Improvement Amendments (US-CLIA). As for the innovatively studied glucose concentrations, a statistically significant difference between the results obtained from ABG (7.8 ± 3.00) mmol·L −1 and venous blood (6.72 ± 2.44) mmol·L −1 was noted ( p < 0.001), with the difference exceeding the TEa of US-CLIA. A linear relationship between venous blood glucose and ABG was obtained: venous blood glucose (mmol·L −1 ) = − 0.487 + 0.923 × ABG glucose (mmol·L −1 ), with R 2 of 0.882. The hemoglobin, potassium, and sodium concentrations in ABG were reliable for guiding treatment in managing COPD emergencies. However, the ABG analysis of glucose was significantly higher as compared to venous blood glucose, and there was a positive correlation between the two methods. Thus, a linear regression equation in this study combined with ABG analysis could be helpful in quickly estimating venous blood glucose during COPD emergency treatment before the standard venous blood glucose was available from the medical laboratory.
multidisciplinary sciences
What problem does this paper attempt to address?
The paper aims to evaluate the accuracy of arterial blood gas (ABG) analysis compared to standard venous blood analysis in measuring hemoglobin, potassium, sodium, and glucose concentrations in patients with chronic obstructive pulmonary disease (COPD), and to compare the differences between the two methods. Specifically, the research objectives are: 1. **Evaluate the accuracy of ABG analysis versus venous blood analysis in measuring hemoglobin, potassium, sodium, and glucose concentrations**: By retrospectively comparing ABG analysis results of COPD patients from January to March 2023 with simultaneously collected venous blood samples, the study assesses the differences between the two methods. 2. **Compare the differences in hemoglobin, potassium, sodium, and glucose concentrations**: Using statistical software (R software), the study evaluates the mean concentration differences of these indicators between ABG analysis and standard venous blood analysis. 3. **Explore the linear relationship of glucose concentration**: The study finds that glucose concentration in ABG analysis is significantly higher than in venous blood glucose concentration and establishes a linear regression equation to estimate venous blood glucose concentration. Through these studies, the authors hope to provide clinicians with reliable evidence for the rapid assessment of hemoglobin, potassium, and sodium concentrations in emergency treatment of COPD, and by combining ABG analysis with the linear regression equation, quickly estimate venous blood glucose concentration before the standard venous blood glucose results are available.