Wire Trapping Technique Combined with Retrograde Approach for Recanalization of Chronic Total Occlusion
Ge Jun-bo,Zhang Feng,Ge Lei,Qian Ju-ying,Wang Hao
DOI: https://doi.org/10.1097/00029330-200809010-00032
2008-01-01
Abstract:Coronary chronic total occlusion (CTO), defined as a total occlusion of duration >3 months, remains a technical challenge for the interventional cardiologists. The major limitation in percutaneous coronary intervention (PCI) of CTO is the inability to penetrate and cross the occlusion with a guidewire. It was reported that the immediate angiographic success rate varied from 50% to 70% using the standard antegrade techniques.1 To improve this suboptimal success rate, the authors firstly introduced retrograde approach through the collateral channels as a novel technique2 and successfully recanalized a left main CTO using this technique when demonstrating the live cases in Transcatheter Cardiovascular Therapeutics (TCT) 2005. Recently, modified techniques based on the retrograde approach have demonstrated that this approach could provide a high success rate with PCI.3-5 In the present report, we described a new method, wire trapping technique combined with retrograde approach, which was applied successfully in three patients with CTO. CASE REPORT Case 1 A 76-year-old male with prior anterior myocardial infarction in 2005 presented with worsening angina. Coronary angiography demonstrated a totally occluded left anterior descending artery (LAD) and there was good collateral flow from the right coronary artery (RCA) to the LAD (Figure 1A). Access was first obtained from the right femoral route and 7 Fr guiding catheter EBU 3.5 (Medtronic, USA) engaged the left coronary ostium. Unfortunately, an attempt to cross the obstruction of the mid-LAD from antegrade approach with a guidewire (Crosswire NT, Terumo, Japan) failed. Considering the optimal collateral channels from the RCA to the LAD, we attempted a retrograde approach. A 6 Fr guiding catheter JR4 (Cordis, USA) from left femoral route engaged the right coronary ostium. A hydrophilic-coated floppy wire (Runthrough, Terumo), supported by a microcatheter (Terumo) in order to protect the channel from injury and achieve better wire maneuverability, was passed in a septal collateral from the posterior descending artery (PDA) which appeared to be connected to the LAD (Figure 1B). Then the guidewire was exchanged to a hydrophilic wire (Crosswire NT) via the microcatheter. Eventually, the wire was advanced up to the distal end of the LAD occlusion through the septal collateral, then crossed the total occlusion of the LAD and entered the aorta (Figure 1C). Following the retrogradely crossing the obstructed LAD, however, a second attempt of antegrade wire failed again, and the retrograde balloon could not yet be delivered to the occlusive site of LAD without predilatation of the septal collateral. Therefore, we attempted to snare the retrograde wire tip into the left guiding catheter using a gooseneck microsnare (Amplatz, USA). Fortunately, the wire was snared successfully into the antegrade catheter from the aorta (Figure 1D), then we pulled back the microsnare slowly and carefully until the retrograde wire was exteriorized out of the antegrade guiding catheter. The occluded LAD was then successfully dilated with an antegrade 1.5 mm × 20.0 mm balloon (Hayate, Terumo) over the retrograde wire (Figure 1E and 1F). Subsequently, a second hydrophilic wire (Crosswire NT) was introduced antegradely, successfully crossing the dilated lesion to the distal segment of the LAD (Figure 1G). Another 2.5 mm × 15.0 mm balloon (Hayate, Terumo) was then used to dilate the lesion for a more optimal predilatation. Before stenting, the 2.5 mm × 15.0 mm balloon was antegradely inserted over the retrograde wire until its tip kissed with the retrograde microcatheter tip and then withdrew the retrograde wire from the antegrade catheter. In this way, the proximal stiff tip of the retrograde wire could be kept in the lumen of microcatheter or balloon in the whole withdrawal process to avoid the vessel injured by the stiff wire tip. Finally, two long drug-eluting stents (Endeavor 3.0 mm × 30.0 mm and 2.5 mm × 30.0 mm, Medtronic) were deployed over the antegrade wire with a good final result (Figure 1H). The patient tolerated the procedure well, and was discharged from the hospital 3 days after this intervention without complications. At the next follow-up visit, the patient was angina-free.Figure 1. (A: ) A diagnostic coronary angiogram showing a chronic occlusive lesion in the middle segment of the LAD with good collaterals from the RCA. (B) A guidewire was retrogradely passed from the RCA to the LAD via a septal branch. (C) The guidewire was guided to the antegrade guiding catheter after it crossed the chronic occlusive lesion retrogradely. (D) The guidewire was snared by a gooseneck microsnare (white arrow) and finally exteriorized out of the antegrade guiding catheter. (E) The antegradely delivered balloon crossed and inflated the chronic occlusive lesion. (F) The LAD restored antegrade flow after balloon inflation. (G) A second antegrade guidewire was passed through the chronic occlusive lesion. (H) The final image of the LAD with two antegradely implanted stents.Case 2 A 51-year-old male with a one-year history of angina underwent diagnostic coronary angiography. The angiogram showed a totally occluded LAD and its ostium could not be identified clearly (Figure 2A and 2B). After the attempt to cross the LAD from anterograde approach failed, a hydrophilic wire (Crosswire NT) was introduced through a 6 Fr guiding catheter AL1 (Cordis) into the RCA. It was advanced retrogradely into the distal LAD through the collateral, then crossed the total obstruction of the LAD and entered the aorta (Figure 2C). A gooseneck microsnare (Amplatz) was inserted through a 7 Fr guiding catheter EBU 3.5 (Medtronic) and snared the retrograde wire tip into the guiding catheter (Figure 2D). However, the retrograde wire tip broke suddenly before we exteriorized it out of the antegrade guiding catheter. We inserted a 2.5 mm × 15.0 mm balloon (Maverick, Boston Scientific, USA) over the antegrade wire and inflated it between the inner wall of the antegrade guiding catheter and the retrograde wire. Then the anchored wire, along with the antegrade catheter and balloon, was pulled out of the sheath. After the balloon deflation, the antegrade guiding catheter engaged the left coronary again and the occluded LAD was then successfully dilatated with the antegrade 1.25 mm × 15.00 mm balloon (Ryujin Plus, Terumo) over the retrograde wire (Figure 2E and 2F). Subsequently, a second wire (Runthrough, Terumo) was introduced antegradely, successfully crossing the dilated lesion to the distal segment of the LAD (Figure 2G). The before-mentioned 2.5 mm × 15.0 mm balloon was then used to inflate the lesion for a more optimal predilatation. After withdrawing the retrograde wire from the antegrade catheter using the same technique described in case 1, two long drug-eluting stents (Firebird 3.5 mm × 29.0 mm and 3.0 mm × 29.0 mm, Microport, China) were deployed over the antegrade wire (Figure 2H). The patient remained asymptomatic after 8-month follow-up.Figure 2. (A): A diagnostic coronary angiogram showing a chronic occlusive lesion in the ostium of the LAD. (B) The RCA provided good collaterals to the LAD. (C) A guidewire was retrogradely passed from the RCA to the LAD via a septal branch. (D) The guidewire was snared by a gooseneck microsnare (white arrow) and finally exteriorized out of the antegrade guiding catheter. (E) The antegradely delivered balloon crossed and inflated the chronic occlusive lesion. (F) The LAD restored antegrade flow after balloon inflation. (G) A second antegrade guidewire was passed through the chronic occlusive lesion. (H) The final image of the LAD with two antegradely implanted stents.Case 3 The patient was a 49-year-old male, presenting with persistent exertional anginal symptoms over the past year despite optimal medical management. He had many risk factors including hypertension, diabetes, hyperlipidemia and current smoking. On diagnostic coronary angiography, the LAD was occluded after the first diagonal branch and was well collateralized from the RCA (Figure 3A). Attempt of antegrade wiring from the right femoral route with a 7F EBU 3.5 guiding catheter (Medtronic) also failed, and then the RCA was engaged from the opposite femoral route with a 6F AL1 guiding catheter (Cordis). A hydrophilic wire (Crosswire NT) was used with a microcatheter (Terumo) for support and was advanced from the RCA through an epicardial collateral into the LAD (Figure 3B). After the retrograde wire crossed the occlusive segment and entered the aorta (Figure 3C), a gooseneck microsnare (Amplatz) was inserted through the antegrade EBU catheter and snared the retrograde wire tip into the guiding catheter (Figure 3D). The retrograde wire tip also broke in the antegrade catheter when we pulled the snare back. We eventually exteriorized the wire using the same method described in case 2. The occluded LAD was then successfully dilatated with a 1.5 mm × 20.0 mm and a 2.5 mm × 20.0 mm antegrade balloon (Ryujin Plus) over the retrograde wire and restored a good antegrade flow with 50% residual stenosis (Figure 3E and 3F). Consequently, two long drug-eluting stents (Firebird 3.5 mm × 29.0 mm and 3.0 mm × 29.0 mm, Microport) were also antegradely deployed over the exteriorized retrograde wire. The final result was optimal (Figure 3G and 3H) and finally the retrograde wire was withdrawn from the antegrade catheter using the same technique described in case 1. The patient remained asymptomatic after 6-month follow-up.Figure 3. (A): A diagnostic coronary angiogram showing a chronic occlusive lesion in the middle segment of the LAD with good collaterals from the RCA. (B) A guidewire was retrogradely passed from the RCA to the LAD via an epicardial collateral. (C) The guidewire was guided to the guiding catheter in the LAD after it crossed the chronic occlusive lesion retrogradely. (D) The guidewire was snared by a gooseneck microsnare (white arrow) and finally exteriorized out of the antegrade guiding catheter. (E) The antegradely delivered balloon crossed and inflated the chronic occlusive lesion. (F) The LAD restored antegrade flow after balloon inflation. (G and H) The final images of the LAD with two antegradely implanted stents.DISCUSSION Retrograde approach has been demonstrated to improve the success rate of PCI for CTOs even in patients with previous failed attempts.3-5 However, even after a retrograde wire successfully passed through the CTO segment, subsequent retrograde balloon dilatation or antegrade wiring sometimes remained unapproachable. The collaterals frequently necessitate a predilation with a small size balloon to allow the retrograde balloon delivery up to the distal CTO site. Although the dilatation of the septal collateral was feasible and safe in most patients, some serious complications, such as collateral perforation and subendocardial hematoma, have been reported in previous literatures.3 To avoid the potential complications associated with septal collateral dilatation, other alternative approaches are required to convert the retrograde wire to an antegrade wire after it has passed through the CTO retrogradely. In this report, we described the treatment of CTOs using a novel technique which combines the retrograde wiring and wire trapping. A retrograde wire across the occlusion was exteriorized out of the antegrade guiding catheter and then acted as an antegrade wire for balloon and stent delivery to recanalize the occlusive lesion. In our small patient population with difficult CTOs (all 3 patients had previous failed antegrade attempts), we were able to demonstrate the feasibility and safety of this novel technique. Successful recanalization was achieved in all 3 patients, and no major complications occurred. The retrograde wire was advanced from the RCA through a septal collateral into the LAD in cases 1 and 2, while it was advanced through an epicardial collateral in case 3. Thus, the exteriorized retrograde wire was not located in distal LAD in cases 1 and 2, but it was still in the main branch of distal LAD in case 3 and the stents could be antegradely deployed over it instead of another antegrade wire. When using wire trapping technique, several key issues should be mentioned. First, before being trapped with a snare, the retrograde guidewire should first pass through the CTO lesion and go directly into the ascending aorta. As the distal cap of the CTO lesions is hypothesized to be thinner and softer than the proximal cap, the success rates of penetrating and crossing the CTO lesion with a specialized hydrophilic wire ranged from 57%-79% even in the patients with previous failed antegrade attempts.3,5 A retrograde wire, which has crossed the occlusive lesion from the distal to the proximal true lumen, is often easily delivered into the ascending aorta. Second, it was frequently very difficult to pull the retrograde wire out of the antegrade catheter and the resistance was very strong especially when the stiff wire segment passed through the tortuous collaterals. The wire tip was often broken in the antegrade catheter and eventually needed an intracatheter anchor balloon to help exteriorize it out. Inserting the retrograde microcatheter over the retrograde wire as far as possible to decrease the wire length barely exposed in the collateral may reduce the difficulties to a certain extent. Finally, when the retrograde wire was withdrawn from the a ntegrade catheter, its proximal stiff tip may injure the collateral and epicardial coronary artery once it gets out of the retrograde microcatheter and exposes into the vessel. Thus, an antegrade balloon or microcatheter should be inserted over the retrograde wire until its tip kissed with the retrograde microcatheter tip before withdrawing the retrograde wire. In this way, the proximal stiff tip of the retrograde wire could be kept in the lumen of microcatheter or balloon in the whole withdrawal process and the injury could be avoided. In conclusion, this novel wire trapping technique combined with retrograde approach could be effectively and safely used in selective patients with CTOs. Such technique could avoid the potential complications associated with collateral dilatation after the retrograde wire has passed through the CTOs.