Safe Removal of Sticky Silicone Oil Using Perfluorocarbon Liquid Injection and Emulsification with a Fragmatome

Hirotsugu Takashina,Akira Watanabe,Tadashi Nakano
DOI: https://doi.org/10.2147/OPTH.S412379
2023-05-29
Clinical Ophthalmology
Abstract:Hirotsugu Takashina, 1 Akira Watanabe, 2 Tadashi Nakano 2 1 Department of Ophthalmology, Tokyo Rosai Hospital, Tokyo, Japan; 2 Department of Ophthalmology, The Jikei University School of Medicine, Tokyo, Japan Correspondence: Hirotsugu Takashina, Department of Ophthalmology, Tokyo Rosai Hospital, 4-13-21 Omori-minami Ota-ku, Tokyo, 143-0013, Japan, Tel +81-3-3742-7301 (ext. 8116), Fax +81-3-3744-9310, Email Purpose: We examine the safe removal of a sticky silicone oil (SO) with an inconspicuous perfluorocarbon liquid (PFCL) layer. Methods: In the first experiment, we injected PFCL into the SO bubble on the bottom of a transparent container or into the chili oil layer of an immiscible droplet composed of PFCL and chili oil on the posterior retina of a vitrectomized pig eye, in order to release the SO bubble or the chili oil layer from the downward adhesion. In the second experiment, we sucked out the SO layer of an immiscible droplet composed of PFCL and SO on the bottom of a transparent container or on the posterior retina of a vitrectomized pig eye using a fragmatome. Results: In the first experiment, the PFCL injection caused the SO bubble to move from the bottom of the transparent container and the chili oil to move from the posterior retina of the pig eye. In the second experiment, when the suction pressure was high, this made it easy and possible to remove the SO layer in the transparent container or the vitrectomized pig eye when emulsification was done by a fragmatome. Conclusion: Moving the SO layer of a sticky SO from the posterior retina after a PFCL injection followed by sucking out of the relocated SO layer using emulsification and high suction pressure through the utilization of a fragmatome can safely remove sticky SO with an inconspicuous PFCL layer. Keywords: silicone oil, perfluorocarbon, fragmatome, emulsification, vitrectomy Sticky silicone oil (SO), which is defined as the unexpected adhesion of an SO bubble to the posterior retina, is one of the refractory complications of SO removal. Not only has sticky SO removal been causing issues over a long period of time, but it has also been reported that there are cases of unexpected occurrences of iatrogenic retinal tears during attempts to forcibly remove the sticky SO. 1,2 It is known that the use of perfluorocarbon liquid (PFCL) during vitrectomy with SO tamponade can cause sticky SO 1–5 and that the prior removal of the PFCL layer between the sticky SO and the retinal surface can make it easier to remove the sticky SO. 3,4 Thus, the identity of a sticky SO is thought to be an immiscible droplet composed of PFCL and SO on the retinal surface. However, only a few previous studies have reported finding a visible PFCL layer between the SO layer of the sticky SO and the retinal surface. 3,4 Moreover, optical coherence tomography performed in another study was not able to detect a PFCL layer between the sticky SO bubble and the retinal surface. 1 Therefore, overall these results suggest that a clearly visible PFCL layer might not actually be present in the majority of sticky SO cases. In our present study, we examined a possible methodology that can potentially be used for the safe removal of a sticky SO with an inconspicuous PFCL layer. The Ethics Committee has ruled that approval was not required for this study, and we adhered to the ARVO Statement for the Use of Animals in Ophthalmic and Vision Research. Two procedures are required in order to perform a safe removal of the sticky SO with an inconspicuous PFCL layer. In the first part, the SO layer of a sticky SO needs to be moved from the retinal surface in order to avoid any histological invasion when sucking out the SO layer. The second part involves the sucking out of the SO layer that was moved of a sticky SO without causing any histological invasion, such as iatrogenic retinal tear. The first part of the procedure involves the moving of the SO layer of a sticky SO from the retinal surface via the use of a PFCL injection. We planned to perform this challenging injection of PFCL into the SO layer of an immiscible droplet composed of PFCL and SO, which is the identity of sticky SO, as creating an enlargement of the immiscible droplet due to the PFCL injection should result in moving of the SO layer from the retinal surface. We applied SO (SILIKON TM 1000; Alcon Laboratories, Inc., Fort Worth, TX) to the dry bottom of a transparent container and then filled the container with water. Subsequently, we then carefully injected additional SO on the original SO application area. The additionally injected SO easily adhered to the original SO application area (Figure 1a), with this viewed as being almost -Abstract Truncated-
What problem does this paper attempt to address?