Effectiveness of Kurtosis-Adjusted Cumulative Noise Exposure in Assessing Occupational Hearing Loss Associated with Complex Noise.
Jiarui Xin,Zhihao Shi,Peiyi Qian,Shuangyan Liu,Yinzhu Hao,Xiangjin Gao,Lifang Zhou,Lei Yang,Meibian Zhang
DOI: https://doi.org/10.1097/aud.0000000000001327
2023-01-01
Abstract:Objectives:Occupational noise-induced hearing loss (NIHL) is one of the most prevalent occupational diseases worldwide. Few studies have been reported on applying kurtosis-adjusted noise energy (e.g., kurtosis-adjusted cumulative noise exposure, CNE-K) as a joint indicator for assessing NIHL. This study aimed to analyze the effectiveness of CNE-K in assessing occupational hearing loss associated with complex noise in typical manufacturing industries. Design:A cross-sectional survey of 1404 Chinese manufacturing workers from typical manufacturing industries was conducted. General demographic characteristics, noise exposure data, and noise-induced permanent threshold shifts (NIPTS) at 3, 4, and 6 kHz (NIPTS346) were collected and analyzed. The role of kurtosis in high-frequency noise-induced hearing loss (HFNIHL) was also analyzed. The degree of overlap of the two logistic curves (i.e., between complex noise CNE-K and HFNIHL%, and between Gaussian noise CNE and HFNIHL%) was used to evaluate the effectiveness of CNE-K, using a stratified analysis based on age, sex, industry, or job type. Results:The binary logistic regression analysis showed that in addition to age, sex, exposure duration, and Eight-hour Continuous Equivalent A-weighted Sound Pressure Level (L-Aeq,L-8h), kurtosis was a key factor influencing HFNIHL% in workers (odds ratio = 1.18, p < 0.05), and its odds ratio increased with an increase in kurtosis value. Multiple linear regression analysis demonstrated that the contribution of kurtosis to NIPTS346 was second to L-Aeq,L-8h. Complex noise led to a higher risk of NIHL than Gaussian noise at frequencies of 3, 4, 6, and 8 kHz after adjusting for age, sex, and CNE (p < 0.05). As kurtosis increased, the notch in the audiogram became deeper, and the frequency at which the notch began to deepen shifted from 3 to 1 kHz. The logistic curve between complex noise CNE-K and HFNIHL% nearly overlapped with that between Gaussian noise CNE and HFNIHL%, and the average difference in HFNIHL% between the two curves decreased from 8.1 to 0.4%. Moreover, the decrease of average difference in HFNIHL% between the two logistic curves was evident in several subgroups, such as male workers, aged <30 and 30 to 50 years, furniture and woodworking industries and gunning and nailing job types with relatively high kurtosis values. Conclusions:Kurtosis, as an indirect metric of noise temporal structure, was an important risk factor for occupational NIHL. Kurtosis-adjusted CNE metric could be more effective than CNE alone in assessing occupational hearing loss risk associated with complex noise.