The effect of pelvic ring rotation and tilt on the radiographic teardrop distance: an important consideration in the assessment of dynamic displacement on stress radiographs

Nicholas J. Tucker,Bryan L. Scott,Austin Heare,Stephen C. Stacey,Cyril Mauffrey,Joshua A. Parry
DOI: https://doi.org/10.1007/s00590-022-03377-x
2022-09-01
European Journal of Orthopaedic Surgery & Traumatology
Abstract:PurposeThe purpose of this study was to determine the effect of rotation and tilt on the radiographic teardrop distance (TD) on anteroposterior (AP) pelvis radiographs.MethodsRadiographic examination of a pelvis models was conducted utilizing increasing degrees of beam rotation and tilt on portable C-arm fluoroscopy. The TD, x-plane rotation (symphyseal-mid-sacrum distance (SMS)), and y-plane tilt (sacroiliac joint-symphysis distance (SIS)) were measured by four independent observers. Interobserver reliability was assessed using intraclass correlations.ResultsTD was altered by less than 2 mm with up to 7.5° fluoroscopic rotation (SMS: 3 cm) and up to 30° of inlet and 15° of outlet (SIS: ± 3.3 cm). SMS distance effectively corresponded to the degree of rotation present (r = 1.00, CI: 0.97 to 1.00, p < 0.0001) and was strongly correlated to TD (r = −0.95, CI: −0.99 to −0.67, p = 0.001). SIS distance effectively corresponded to the degree of tilt present (r = −0.97, CI: −0.99 to −0.88, p < 0.0001) and was correlated to TD (r = 0.94, CI: 0.75 to 0.99, p = 0.0001). Linear regression models determined that, with every degree of rotation and tilt, TD was altered by 0.4 mm and 0.09 mm, respectively (p = 0.0004, r2 = 0.93 and p < 0.0001, r2 = 0.94, respectively). Interobserver reliability among observers was excellent (0.92).ConclusionThe TD has excellent interobserver reliability and is minimally impacted by up to 7.5° of rotation, 30° inlet tilt, and 15° of outlet tilt. Utilization of these thresholds may ensure reliability of TD measurements when assessing pelvis stress radiographs.
What problem does this paper attempt to address?