Levels and Factors of Nurses' Alarm Fatigue in Critical Care Settings in Saudi Arabia: A Multicenter Cross-Sectional Study
Sameer Alkubati,Salman Alsaqri,Gamil Alrubaiee,Mokhtar Almoliky,Talal Alqalah,Eddieson Pasay-An,Awatif Alrasheeday,Shimmaa Elsayed
DOI: https://doi.org/10.2147/jmdh.s452933
2024-02-22
Journal of Multidisciplinary Healthcare
Abstract:Sameer A Alkubati, 1 Salman Hamdan Alsaqri, 1 Gamil G Alrubaiee, 2 Mokhtar Abdu Almoliky, 1 Talal Ali Hussein Alqalah, 1 Eddieson Pasay-An, 3 Awatif Mansoor Alrasheeday, 4 Shimmaa Mohamed Elsayed 5 1 Department of Medical Surgical Nursing, University of Hail, Hail, Saudi Arabia; 2 Department of Community Health, University of Hail, Hail, Saudi Arabia; 3 Fundamental of Nursing Department, King Khalid University, Abha, Saudi Arabia; 4 Nursing Administration Department, University of Hail, Hail, Saudi Arabia; 5 Critical Care and Emergency Nursing Department, Damanhour University, Damanhour, Egypt Correspondence: Sameer A Alkubati, Department of Medical Surgical Nursing, University of Hail, Hail, Saudi Arabia, Tel +966506575284, Email Background: A continuous and high frequency of alarms from monitoring and treatment devices can lead to nurses' sensory exhaustion and alarm fatigue in critical care settings. Aim: The purpose of this study was to evaluate the level of alarm fatigue and determine the relationship between nurses' sociodemographic and work-related factors and the level of alarm fatigue in critical care settings in Hail City, Saudi Arabia. Methods: Between May and July 2023, 298 nurses who worked in the emergency, intensive care, and critical care units of all the public hospitals in Hail City participated in a cross-sectional survey. Sociodemographic and work-related sheet and the Nurses' Alarm Fatigue Questionnaire were used to collect data. Results: The total mean score of alarm fatigue was 26.38± 8.30 out of 44. The highest score was observed for the item "I pay more attention to the alarms in certain", while the lowest score were observed for the items "I turn off the alarms at the beginning of every shift" with mean scores of 2.51 and 1.61, respectively. Nurses who were males, older than 30 years and Saudi citizens had significantly higher mean scores of alarm fatigue than their counterparts. In addition, significantly higher mean scores of alarm fatigue were noticed for nurses experienced for 10 years or more and who had regular morning shifts. Multiple linear regression showed that male (p=0.014), age (p=0.012), and Saudi nationality (p < 0.029) were the independent factors affecting the level of fatigue alarm among nurses. Conclusion: Nurses working in critical care settings at hospitals in Hail city are exposed to average levels of alarm fatigue, which can be influenced by sex, age, nationality, and experience of nurses. Therefore, it is imperative to manage alarm fatigue in critical care units by considering work-related and personality-related factors to ensure patient safety. Keywords: alarms, fatigue, nurses, intensive care units, emergency The advancement of technology has led health agencies and healthcare providers (HCPs) to use various devices and equipment, such as ventilators, monitors and infusion pumps, to provide the best medical care, particularly in critical and intensive care units (ICUs). 1 These devices and equipment enable continuous monitoring of stability and any changes in physical hemodynamic conditions related to disease and the administration of medications. 1–3 Warning systems are commonly included in monitoring and treatment devices used by healthcare institutions and help to make HCPs, especially nurses, aware of any abnormalities in either the patient's physiologic status or the devices. 2–4 However, these devices may produce large numbers of alarms that can lead to sensory exhaustion for the nurses during their work, interrupt them and affect their responses to alarms, a condition known as alarm fatigue. 5 Alarm fatigue occurs when medical professionals are overexposed to alerts, it can cause sensory overload and lead to missed and desensitized alarms. 6 It may negatively affect the nurses' quality of care as well as the patient safety. In one hospital's emergency departments in Finland, a study revealed that various medical equipment generated 28,176 alarms in one month, or about 125 alarms per monitor each day. 7 In South Korea, approximately 2184 clinical alarms were detected in ICUs over two days, ie, 45.5 clinical alarms per hour, with 63.8% of these being false alarms. 8 As a result, the Emergency Care Research Institute (ECRI) identified clinical alarms and alarm overload as one of the main ten health medical technology concerns in 2020. 9 Nurses in ICUs and emergency departments are the main HCPs responsible for responding to and dealing with clinical alarms, but they may experience an excessive number of clinical alarms and repeated fal -Abstract Truncated-
health care sciences & services