Stability Analysis of Active Front End and Permanent Magnet Synchronous Generator With Back EMF-Based Sensorless Control for DC Marine Vessels

Young-Wook Kim,Seung-Ki Sul
DOI: https://doi.org/10.1109/tpel.2022.3233889
IF: 5.967
2023-04-01
IEEE Transactions on Power Electronics
Abstract:This article studies the influence of sensorless control on the permanent magnet synchronous generator (PMSG) and pulsewidth modulation (PWM) converter (active front end rectifier, AFE) system for dc marine vessels. Back EMF-based sensorless control is adopted in this article because the minimum speed of PMSG in a dc marine vessel is enough for obtaining a sufficient back EMF signal. First, the output impedance of PMSGAFE system with a typical topology and controller is deduced by small-signal analysis. The stability analysis with constant power load (CPL) is analyzed, including the influence of sensorless control bandwidth on PMSG with a significant per-unit impedance value. Since the inductance parameter affects both the current control and sensorless control, the influence of error in the estimated inductance parameter on the stability of PMSGAFE system is analyzed. To verify the proposed impedance model, output impedance is measured in the simulation and experiment. The stability analysis with the proposed impedance model and load impedance of CPL is provided in MATLAB, and simulation results and experimental measurements are given to verify the analysis.
engineering, electrical & electronic
What problem does this paper attempt to address?