Correlation of Extractables Transfer from Low-Density Polyethylene into Extraction Solvents with Abraham Solvation Parameter Model and Assessment of Thermodynamic and Kinetic Effects in Achieving Exhaustive Extractions in Chemical Characterization of Medical Devices

By Jianwei Li
DOI: https://doi.org/10.1007/s10953-023-01286-z
2023-05-12
Journal of Solution Chemistry
Abstract:The thermodynamic and kinetic contributions to an exhaustive extraction of medical devices are studied using the Abraham solvation parameter model and a systematic analysis of the material–solvent interactions, using low-density polyethylene (LDPE) as an example material and extraction solvents of varying polarities. The thermodynamic distribution of extractables compounds between LDPE and solvents of different polarities (water as polar, methanol/ethanol as semipolar, and hexane as nonpolar), used in the exhaustive extraction of medical devices, are first correlated by Abraham solvation parameter model using experimental data. The constructed models are used to derive the partition coefficient between LDPE and various solvents for the representative extractables entities over a wide hydrophobicity range in (the octanol–water partition coefficient) from − 1 to 18. The derived partition coefficients are then used to compute the extraction efficiency by a repeated extraction with five extraction cycles. The ranges of partition coefficient and extraction efficiency by each solvent or three combined solvents allow the assessment of the exhaustive extraction coverage over the hydrophobicity range. In addition to the thermodynamic analysis, the kinetic contribution to the exhaustive extraction by each solvent is also analyzed systematically, starting from the LDPE–solvent interaction, as indicated by a material swelling, to a consequential change in diffusion coefficient, and to a solvent-dependent release rate. The ratios of experimental diffusion coefficients of extractables by hexane extraction to that by alcohol extraction are collected to demonstrate the impact of solvent swelling on the diffusion and release of extractables. The ratios of amounts of extractables released by 24-h and 72-h extraction cycles, recommended by ISO 10993-12 (2021), are also collected to show the influence of cycle time on extraction efficiency. It is concluded from the study that the three solvents of varying polarities are very adequate to extract LDPE to exhaustion over the hydrophobicity range ( from − 1 to 18) or beyond. The extraction by water and methanol/ethanol is a slower "diffusion-controlled" process, compared to a faster "relaxation-controlled" process by hexane. It is also demonstrated that the use of 72-h extraction cycle time has no realistic advantage. The 24-h extraction cycle time is a better choice in achieving an exhaustive extraction efficiently, particularly for extractables with a very slow migration kinetics.
chemistry, physical
What problem does this paper attempt to address?