Dielectrophoresis Separation of Platelets Using a Novel Zigzag Microchannel

Yanfang Guan,Yansheng Liu,Hui Lei,Shihua Liu,Fengqian Xu,Xiangxin Meng,Mingyang Bai,Xiaoliang Wang,Gexuan Yang
DOI: https://doi.org/10.3390/mi11100890
IF: 3.4
2020-09-25
Micromachines
Abstract:Platelet separation and purification are required in many applications including in the detection and treatment of hemorrhagic and thrombotic diseases, in addition to transfusions and in medical research. In this study, platelet separation was evaluated using a novel zigzag microchannel fluidic device while leveraging a dielectrophoresis (DEP) electric field using the COMSOL multiphysics software package and additional experimentation. The zigzag-shaped microchannel was superior to straight channel devices for cell separation because the sharp corners reduced the required horizontal distance needed for separation and also contributed to an asymmetric DEP electric field. A perfect linear relationship was observed between the separation distance and the corner angles. A quadratic relationship (R2 = 0.99) was observed between the driving voltage and the width and the lengths of the channel, allowing for optimization of these properties. In addition, the voltage was inversely proportional to the channel width and proportional to the channel length. An optimal velocity ratio of 1:4 was identified for the velocities of the two device inlets. The proposed device was fabricated using laser engraving and lithography with optimized structures including a 0.5 mm channel width, a 120° corner angle, a 0.3 mm channel depth, and a 17 mm channel length. A separation efficiency of 99.4% was achieved using a voltage of 20 V and a velocity ratio of 1:4. The easy fabrication, lower required voltage, label-free detection, high efficiency, and environmental friendliness of this device make it suitable for point-of-care medicine and biological applications. Moreover, it can be used for the separation of other types of compounds including lipids.
chemistry, analytical,nanoscience & nanotechnology,instruments & instrumentation,physics, applied
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to achieve effective separation and purification of platelets under the action of dielectrophoresis (DEP) electric field by using a new type of zig - zag microchannel fluidic device. Platelet separation and purification are necessary in many applications, including detection and treatment of hemorrhagic and thrombotic diseases, blood transfusion, and medical research, etc. Although traditional separation methods such as centrifugation are widely used, they have problems such as the need for professional equipment, complex operation, high cost, and being not suitable for point - of - care testing (POCT). Therefore, this paper proposes a dielectrophoresis separation technology based on zig - zag microchannels, aiming to overcome the limitations of traditional methods and provide a simple, low - cost, efficient, and environmentally - friendly cell - separation solution. Specifically, the paper solves the above problems through the following aspects: 1. **Design Optimization**: A microchannel structure with a unilateral zig - zag arrangement is proposed to achieve a uniform potential distribution within the microfluidic chip channels. This design replaces the traditional DEP devices with double - layer rectangular or semicircular electrode configurations, improving the separation efficiency and reducing the loss rate during particle movement. 2. **Theoretical Analysis**: The COMSOL multiphysics simulation software package is used to simulate the electric field distribution in the zig - zag microchannels, and the separation effects on particles of different sizes are verified by experiments. It is found that the zig - zag microchannels require a shorter horizontal separation distance compared to the straight - line microchannels and can generate an asymmetric DEP electric field, which is beneficial for improving the separation efficiency. 3. **Parameter Optimization**: By changing structural parameters such as corner angles, channel widths, and lengths, the influence of these factors on the separation effect is studied. The results show that there is a linear relationship between the corner angle and the separation distance, while a quadratic relationship is presented between the driving voltage and the channel width and length. In addition, the optimal value of the inlet velocity ratio is determined to be 1:4 to achieve the best separation effect. 4. **Experimental Verification**: The optimized microfluidic chip is fabricated by laser engraving and photolithography techniques. The experimental results show that under the conditions of a voltage of 20V and a velocity ratio of 1:4, the separation efficiency reaches 99.4%. In conclusion, through the innovative zig - zag microchannel design and dielectrophoresis technology, this paper successfully solves the key problems in platelet separation and purification, providing new possibilities for point - of - care testing and biological applications.