Emission characteristics and assessment of odors from sludge anaerobic digestion with thermal hydrolysis pretreatment in a wastewater treatment plant

Zhangliang Han,Ruoyu Li,Hanzhang Shen,Fei Qi,Baoxian Liu,Xiue Shen,Lin Zhang,Xiaoju Wang,Dezhi Sun
DOI: https://doi.org/10.1016/j.envpol.2021.116516
IF: 8.9
2021-04-01
Environmental Pollution
Abstract:<p>Anaerobic digestion (AD) with thermal hydrolysis pre-treatment (THP) is an effective sludge treatment method which provides several advantages such as enhanced biogas formation and fertilizer production. The main limitation to THP-AD is that hazardous odors, including NH<sub>3</sub> and volatile sulfur compounds (VSCs), are emitted during the sludge treatment process. In order to develop strategies to eliminate odors, it is necessary to identify the key odors and emissions sites. This study identified production of NH<sub>3</sub> (741.60 g·dry sludge t<sup>-1</sup>) and VSCs (277.27 g·dry sludge t<sup>-1</sup>) during sludge AD after THP, and measured emissions in each of the THP-AD sludge treatment sites. Odor intensity, odor active values, permissible concentration-time weighted average, and non-carcinogenic risks were also assessed in order to determine the sensory impact, odor contribution, and health impacts of NH<sub>3</sub> and VSCs. The results revealed that odor pollution existed in all of the test sites, particularly in the sludge pump room and pre-dehydration workshop. NH<sub>3</sub>, H<sub>2</sub>S, and methyl mercaptan caused very strong odors, and levels of NH<sub>3</sub> and H<sub>2</sub>S were enough to impact the health of on-site employees.</p>
environmental sciences
What problem does this paper attempt to address?