Digital Clock and Recall: a digital, process-driven evolution of the Mini-Cog
Joyce Gomes-Osman,Soo Borson,Claudio Toro-Serey,Russell Banks,Marissa Ciesla,Ali Jannati,W Isaiah Morrow,Rod Swenson,David Libon,David Bates,John Showalter,Sean Tobyne,Alvaro Pascual-Leone
DOI: https://doi.org/10.3389/fnhum.2024.1337851
2024-08-26
Abstract:Introduction: Alzheimer's disease and related dementias (ADRD) represent a substantial global public health challenge with multifaceted impacts on individuals, families, and healthcare systems. Brief cognitive screening tools such as the Mini-Cog© can help improve recognition of ADRD in clinical practice, but widespread adoption continues to lag. We compared the Digital Clock and Recall (DCR), a next-generation process-driven adaptation of the Mini-Cog, with the original paper-and-pencil version in a well-characterized clinical trial sample. Methods: DCR was administered to 828 participants in the Bio-Hermes-001 clinical trial (age median ± SD = 72 ± 6.7, IQR = 11; 58% female) independently classified as cognitively unimpaired (n = 364) or as having mild cognitive impairment (MCI, n = 274) or dementia likely due to AD (DLAD, n = 190). MCI and DLAD cohorts were combined into a single impaired group for analysis. Two experienced neuropsychologists rated verbal recall accuracy and digitally drawn clocks using the original Mini-Cog scoring rules. Inter-rater reliability of Mini-Cog scores was computed for a subset of the data (n = 508) and concordance between Mini-Cog rule-based and DCR scoring was calculated. Results: Inter-rater reliability of Mini-Cog scoring was good to excellent, but Rater 2's scores were significantly higher than Rater 1's due to variation in clock scores (p < 0.0001). Mini-Cog and DCR scores were significantly correlated (τ B = 0.71, p < 0.0001). However, using a Mini-Cog cut score of 4, the DCR identified more cases of cognitive impairment (n = 47; χ 2 = 13.26, p < 0.0005) and Mini-Cog missed significantly more cases of cognitive impairment (n = 87). In addition, the DCR correctly classified significantly more cognitively impaired cases missed by the Mini-Cog (n = 44) than vice versa (n = 4; χ 2 = 21.69, p < 0.0001). Discussion: Our findings demonstrate higher sensitivity of the DCR, an automated, process-driven, and process-based digital adaptation of the Mini-Cog. Digital metrics capture clock drawing dynamics and increase detection of diagnosed cognitive impairment in a clinical trial cohort of older individuals.