Analysis of False-Positive and False-Negative Results in 99Mtc-Mibi SPECT/CT Parathyroid Imaging
Yan Liu,Lulu Yang,Hui Xu,Yiyuan Yang,Yiqian Liang,Aimin Yang,Xiaojiang Tang,Shengkai Lei,Ioannis Christakis,Pornpeera Jitpratoom,Jianjun Xue
DOI: https://doi.org/10.21037/qims-23-1091
2023-01-01
Quantitative Imaging in Medicine and Surgery
Abstract:Background: Exact preoperative localization is desirable to perform minimally invasive parathyroidectomy for hyperparathyroidism (HPT). This study aimed to evaluate the diagnostic values of Tc-99m-methoxyisobutylisonitrile (Tc-99m-MIBI) single photon emission computed tomography /computed tomography (SPECT/CT) of parathyroid glands by analyzing the relationship between lesion weight and false-negative (FN) results, as well as to explain the possible reason. Methods: The data from 314 patients with suspected HPT who underwent Tc-99m-MIBI SPECT/CT parathyroid imaging between 2011 and 2022 were retrospectively evaluated. The sensitivity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of parathyroid Tc-99m-MIBI SPECT/ CT were calculated, and the false-positive (FP) and FN findings were analyzed. Results: Accurate localization by Tc-99m-MIBI SPECT/CT was significantly associated with the parathyroid hormone (PTH) level. The Tc-99m-MIBI SPECT/CT for diagnosis/lesion location reached a sensitivity of 84.6%/56.8%, a PPV of 97.3%/98.4%, an NPV of only 23.7%/4.18%, and an accuracy of 83.4%/57.1%, respectively. The largest diameter, shortest diameter, and lesion volume were lower in the FN group than in the TP group. A total of 7 FP cases were found, including 2 cases of thyroid nodules, 4 cases of thyroid tissue, and 1 case of hibernoma. A total of 45 FN patients, including 321 FN lesions, were confirmed, of which parathyroid hyperplasia accounted for 97.8%. Lesion weights greater than 20 mu g were able to be detected, but lightweight lesions less than 100 mg were the principal source of FN results, accounting for approximately 39.3%. With lesion weights 0-100, 101-300, 301-1,000, and >1,000 mg, the FN rate was 70.8% (126/178), 51.8% (103/199), 34.6% (81/234), and 8.33% (11/132), respectively. Conclusions: Tc-99m-MIBI SPECT/CT parathyroid imaging provides good sensitivity and high specificity in HPT location. Correct localization by Tc-99m-MIBI SPECT/CT correlates positively with lesion weight and PTH levels. The smaller the lesion, the higher the FN rate in Tc-99m-MIBI SPECT/CT parathyroid imaging, and lesions weighing less than 100 mg are the main source of FN results in Tc-99m-MIBI SPECT/ CT parathyroid imaging.