A Novel Pentachlorophenol Electrochemical Sensor Based on Nickel-Cobalt Layered Double Hydroxide Doped with Reduced Graphene Oxide Composite

Hicham Meskher,Fethi Achi,Fatah Ben Moussa,Abdellah Henni,Hakim Belkhalfa
DOI: https://doi.org/10.1149/2754-2734/acc117
2023-03-04
ECS Advances
Abstract:A highly sensitive non-enzymatic electrochemical pentachlorophenol (5-CP) sensor was successfully fabricated employing a multi-component sensing platform made of nickel-cobalt layered double hydroxide (NiCo-LDH) supported on green organic-inorganic nanohybrid (rGO-CuO) drop-casted on a gold electrode. The chemical and morphological properties of the as-synthesized nanostructures were investigated and confirmed by infrared spectroscopy and scanning electron microscopy. The electrochemical measurements results demonstrated that both the good conductivity of NiCo-LDH/rGO-CuO favors the electrochemical redox reaction of 5-CP and the large accessible active surface area of the hierarchical structure boosted by rGO-CuO. In the optimized procedure, we have evaluated the analytical performance of the NiCo-LDH/rGO-CuO/AuE using cyclic voltammetry based on the current intensities of the redox peaks. Our findings indicate that the developed NiCo-LDH/rGO-CuO/AuE sensor exhibits a wide linear range from 1 to 50 μM while thelimit of detection was estimated to be 12.64 μM for 5-CP. Moreover, the suggested 5-CP sensor displayed an excellent stability that might provide a robust sensing platform for the practical and reliable detection of 5-CP in various real samples.