Fundamental study for heat pump stack length determination with complex flow paths in a compact thermoacoustic system

Satoru Ono,Shin-ichi SAKAMOTO
DOI: https://doi.org/10.35848/1347-4065/acb1bc
IF: 1.5
2023-02-07
Japanese Journal of Applied Physics
Abstract:The miniaturization of thermoacoustic systems is expected to find practical applications in various fields. To achieve miniaturization, we focused on the relation of the sound wave in the tube and the length of the heat-pump stack. Accordingly, three types of metal meshes with different channel diameters were prepared, and thermoacoustic systems were designed considering ωτ, a dimensionless quantity. In the experiment, the stack length was varied and the stack temperature difference and heat flow were measured. Consequently, temperature difference and heat flow with respect to the stack length were studied. In addition, even when the stack was short, temperature difference at both ends of the stack was formed. The better stack length in terms of energy efficiency was also examined. Accordingly, we confirmed that the ratio of stack length to wavelength is in the range of 0.2%–0.6%.
physics, applied
What problem does this paper attempt to address?