Electroactive bacteria as whole-cell biosensor for sensitive detection of hydrogen peroxide

Junlin Wen,Daigui He,Tongye Zhuo,Wanqing Li,Jianbo Liu,Jialin Wu,Yurong Zhao,Yong Yuan
DOI: https://doi.org/10.1016/j.jece.2023.109333
IF: 7.7
2023-01-26
Journal of Environmental Chemical Engineering
Abstract:Hydrogen peroxide (H 2 O 2 ) is a widely used strong oxidizer and has harmful effects on human health with excessive exposure. Herein, we proposed a simple and effective method for H 2 O 2 detection by utilizing electroactive bacteria (EAB) as a whole-cell biosensor. The proposed method was achieved by utilizing the multiheme c -type cytochromes (central components of microbial extracellular electron transfer) of model EAB Shewanella oneidensis MR-1 to catalyze the oxidation of tetramethylbenzidine in the presence of H 2 O 2 . Owing to the excellent peroxidase-like activity of the multiheme c -cyts, this H 2 O 2 detection method has a wide dynamic range between 0.1 and 1000 μM and a low detection limit of 0.17 μM. The proposed method, when coupled with glucose oxidase, displayed a high sensitivity (0.57 μM) and broad linear range (1 μM - 10 mM) for glucose. Moreover, this method has high specificity and good recovery for detecting H 2 O 2 -spiked real samples. Overall, this study has developed a novel biosensing platform that provides an alternative approach to H 2 O 2 detection.
engineering, chemical, environmental
What problem does this paper attempt to address?