Research on ampoule liquid medicine sub-pixel image registration based on modified phase-only correlation

Weng Fa-lu
Abstract:Mechanical parts’ manufacturing and assembling accuracy,offset load force,asynchrony between tracing arm and CCD cameras can cause random displacements at different degree during ampoule sequential image acquisition in vision-based foreign particle image inspection system.These displacements will bring great challenges to the recognition of the visible particles in the liquid.Therefore,a simplified phase-only correlation based on sub-pixel image registration algorithm is proposed which can greatly reduce the computation complexity.According to the experiments,the running time is reduced sharply from maximal 9.1843 s to 0.1331 s under the condition of keeping the same registration accuracy and error.The proposed algorithm improves the registration real-time and lays a solid foundation for the following foreign particle extraction.
Engineering
What problem does this paper attempt to address?