Umbilical cord gas analysis: clinical implications of a comprehensive, contemporary determination of normal ranges
Kelly D Albrecht,Stacie Denning,Kathleen Hosek,Brian A Burnett,Haleh Sangi-Haghpeykar,Michael A Belfort,Steven L Clark
DOI: https://doi.org/10.1016/j.ajogmf.2023.101134
Abstract:Background: Umbilical cord gases are often used to assess the impact of labor and delivery on the fetus. However, no large series exists that reflects contemporary obstetrical practice or that analyzed blood gas ranges by route of delivery. Baseline, prelabor acid-base status in the human fetus is also poorly defined, rendering the assessment of blood gas changes during labor difficult. Objective: This study aimed to define normal umbilical cord gas and lactate values, stratified by mode of delivery, in a large contemporary series in which universal umbilical cord gas evaluation was dictated by protocol. Study design: This was a retrospective cohort study. We analyzed the umbilical cord gas and lactate data of an unselected population of infants born between March 2012 and April 2022 at a large teaching hospital. These values were then analyzed by mode of delivery and, for cesarean deliveries, by indication for cesarean delivery and type of anesthesia. Umbilical cord gas values from infants delivered by elective cesarean delivey under general anesthesia without labor were considered representative of baseline, prelabor values. Results: Data were available for 45,475 infants. The median arterial pH values and interquartile ranges for vaginal births, elective cesarean deliveries without labor, and cesarean deliveries performed for fetal heart rate concerns were 7.27 (0.09), 7.27 (0.06), and 7.25 (0.09), respectively. Arterial lactate values for these same 3 groups were 4.1 (2.5), 2.5 (1.2), and 4.0 (2.8) mmoles/L, respectively. Because of the very large sample size, most comparisons yielded differences that were statistically significant, but clinically irrelevant. Of all the infants, 14% had an arterial pH <7.20; a pH value of 7.1 represents 2 standard deviations from the mean. Conclusion: This large, population-based study of umbilical cord gas and lactate levels in an unselected population, stratified by delivery mode, represents a previously unavailable benchmark for the evaluation of umbilical cord gases. Arterial umbilical cord pH values for infants delivered by elective caesarean delivery without labor (median pH 7.28) reflect a lower prelabor fetal pH baseline than previously assumed. This finding, coupled with our determination that a 2 standard deviation below normal pH limit of 7.1, instead of the historic arbitrary pH of 7.2 threshold, helps to explain the poor positive predictive value of electronic fetal heart rate monitoring, a test designed to detect arterial pH levels that have fallen from an assumed baseline near pH 7.4 to an assumed potentially injurious pH level of <7.2. Uncomplicated labor, even when prolonged, does not generally lead to a clinically significant cumulative hypoxic stress to the human fetus. These findings, along with our determination that there is no difference in the acid-base status among infants delivered by cesarean delivery for fetal heart rate concerns, help to explain the failure of current approaches in labor and delivery management to reduce the rates of neonatal hypoxic-ischemic encephalopathy and cerebral palsy, conditions that almost always reflect developmental events rather than the effects of labor on the fetus.