Strontium and cesium contamination behavior on Q235b carbon steel of radioactive liquid waste tank in alkaline environment

Yu Gu,Yi Zhang,Xin-Wei Li,Shi-Cheng Bi,Zuo-Xi Zheng
DOI: https://doi.org/10.1007/s10967-022-08722-2
2023-01-03
Journal of Radioanalytical and Nuclear Chemistry
Abstract:Q235b carbon steel, main material of early alkaline radioactive liquid waste tank, can be contaminated by 90 Sr and 137 Cs. In this work, batch contamination experiments were conducted to simulate contamination of steel. The results indicated that Fe 3 O 4 , main corrosion product, fell off to form sludges. Furthermore, Sr existed mainly in form of SrCO 3 in oxide layer and sludge, and the corrosion made Sr enter into corrosion defects. While Cs was more limited to surface, mainly in form of CsNO 3 on the surface of oxide layer and sludge. The findings of this work will facilitate the development of efficient decontamination techniques.
chemistry, inorganic & nuclear, analytical,nuclear science & technology
What problem does this paper attempt to address?