Abstract:Objective:We aimed to evaluate the efficacy and safety of one-stage hybrid approach (thoracoscopic surgical ablation combined with catheter ablation) in the treatment of refractory atrial fibrillation (AF) , and preliminarily summarized the experience.Methods:Twenty-one patients with refractory AF (including persistent AF, long-standing persistent AF and paroxysmal AF with repeated failures of catheter ablation) who underwent one-stage hybrid approach in Shanghai Sixth People’s Hospital from August 2015 to January 2018 were selected, including 14 males and 7 females, with an average age of (63±11) years, and the median duration of AF was 3 years. Firstly, bilateral pulmonary veins were ablated by thoracoscopic approach through bilateral chest wall, Marshall ligament was cut off, and left atrial appendage was ligated. After that, three-dimensional modeling of the left atrium was performed, and the integrity of surgical ablation pathway was verified and residual conduction was blocked by catheter endocardium pathway combined with voltage mapping. The endpoint of ablation was pulmonary vein isolation. The patients were followed up regularly at 6, 12, 18 and 24 months after operation.Results:Twenty-one patients achieved electrical isolation of bilateral pulmonary veins. After an average of (32±10) months, surgery related complications occurred in 2 cases, and three died. At the 6
th month of follow-up, 71.4% (15/21) of the patients maintained sinus rhythm, at the 12
th month of follow-up, 57.1% (12/21) of the patients maintained sinus rhythm, at the 18
th month of follow-up, 50.0% (10/20) of the patients maintained sinus rhythm. There were 11 cases of recurrence, including 4 cases of atrial flutter and 7 cases of AF. Three patients underwent re-catheter ablation, of which 2 patients recovered sinus rhythm. It was found that in the long-term follow-up, the intervention of hybrid surgery for pulmonary vein potential isolation was still thorough. The overall success rate after re-catheter ablation or cardioversion was 71.4% (15/21) . One year after the hybrid approach, the mean left atrial diameter was (48.4±7.0) mm, and the mean left ventricular ejection fraction was 64%±4%, which was improved compared with preoperative condition, but the difference was not statistically significant (
P>0.05) .
Conclusion:As a new type of operation, one-stage hybrid approach has solved many difficult problems that couldn’t be solved only by internal medicine or surgery treatment itself, and has also made up for their limitations. As far as the current experience of our center, for patients with refractory AF, hybrid treatment has a higher success rate and fewer complications, which preliminarily confirmed its safety and effectiveness.